5.  There are three rocker type light controls located on top surface of microscope base. 
 

MAIN  =  Turns power on and off 
“I”   

=  Turns incidental light on (top illumination) 

“T”   

=  Turns transmitted light on (substage illumination) 

 

REMEMBER to never operate bottom (transmitted) light with plastic stage plate in use. 

 
6.  Place object to be viewed on center of stage surface. 
 
7.  Turn objective turret until smaller number (lowest magnification) is towards front of microscope (away 

from post), making certain that turret “clicks” into indexed position. 

 

Magnification is determined by multiplying the number on the eyepieces times the number on the 
objective turret.  For example, if your microscope is equipped with 10x eyepieces and the turret is 
positioned so that a 3 is indexed at the front of the microscope, the magnification resulting will be 30 
times. 

 

To change magnification, turn objective turret 90

º

 until it “clicks” into position with another number on 

turret facing to the front of the microscope.  Your microscope is parfocalled, and only slight adjustment 
of the focusing knobs may be required after changing from one magnification to the other. 

 

 

Specification Chart

 

 

 

Eyepiece 

 

 

Objective 

 WF10X 

(supplied)

 

WF15X 

(optional)

 

 

 

Maximum 

 

Total 

Magnification 

Field 

Size 

Total 

Magnification 

Field 

Size 

Working 

Distance 

Specimen 

Height 

1X 

10X 

20mm 

15X 

13mm 

75mm 

60mm 

3X 

30X 

6.6mm 

45X 

4.3mm 

 

 

 

 

 

 

 

2X 

20X 

10mm 

30X 

6.5mm 

75mm 

60mm 

4X 

40X 

5mm 

60X 

3.2mm 

 

 

 

 

 

 

 

1X 

10X 

20mm 

15X 

13mm 

75mm 

60mm 

2X 

20X 

10mm 

30X 

4.5mm 

 
8.  Before making close observations, the following steps should be taken to adjust the microscope for 

your particular eyesight and for specimen size.  Note that all stereo microscopes permit you to 
examine opaque, 3-dimensional objectives.  Stereo models having substage (transmitted) illumination 
permit you to also view transparent specimen or prepared slides when the glass stage plate is in 
place. 

 

A.  Turn the focusing knobs until they are positioned in the middle of their range of travel. 
 
B.  Holding the microscope head with one hand, loosen locking knob at back of post to permit the 

head to move up and down on post until specimen comes into approximate focus.  Retighten 
locking knob. 

 
C.  Looking through microscope with both eyes, grasp both sides of microscope head and gently 

push eyepiece tubes together or pull apart until the two images blend together into one image.  
This adjusts the interpupillary distance between eyepieces to match that of your own eyes. 

 
D.  Looking through right side of microscope with right eye, adjust image sharpness by turning the 

focusing knobs. 

 

Summary of Contents for 447TBL

Page 1: ...Instruments Inc 6508 Tri County Parkway Schertz Texas 78154 Phone 210 590 9010 Fax 210 590 1104 INSTRUCTIONS FOR MODELS 446TBL 447TBL AND 448TBL STEREOSCOPIC MICROSCOPES Copyright 1 2 01 National Optical Scientific Instrument Inc ...

Page 2: ...urret Head position locking screw Focusing knob Base Stage Plate Stage Clips Top light housing Head retaining screw one on each side Light control switches Power switch Post locking knob Fuse Rubber eyeshields Light housing locking knob Locking set screw located on side ...

Page 3: ...ntainer and then pack the styrofoam in another corrugated shipping container for optimum protection Use of the styrofoam alone will not provide adequate protection in transit and will void your warranty ASSEMBLY OPERATION 1 Install rubber eyepiece shields over top of eyepieces with the flared portion of the shields positioned at the outside edge of eyepieces These help block out undesired light re...

Page 4: ...ve WF10X supplied WF15X optional Maximum Total Magnification Field Size Total Magnification Field Size Working Distance Specimen Height 1X 10X 20mm 15X 13mm 75mm 60mm 3X 30X 6 6mm 45X 4 3mm 2X 20X 10mm 30X 6 5mm 75mm 60mm 4X 40X 5mm 60X 3 2mm 1X 10X 20mm 15X 13mm 75mm 60mm 2X 20X 10mm 30X 4 5mm 8 Before making close observations the following steps should be taken to adjust the microscope for your...

Page 5: ...ood source of air C To clean eyepiece lenses do not remove from eyepiece tube Clean only the outer lens surface Breath on lens to dampen surface then wipe with lens paper or tissue or use a cotton swab moistened with distilled water Wipe lenses with a circular motion applying as little pressure as possible Avoid wiping dry lens surface as lenses are scratched easily If excessive dirt or grease get...

Page 6: ...ear left side of microscope base To remove fuse from holder insert a 6mm screwdriver blade into slot located in rear of fuse holder cap Slightly depress and rotate screwdriver turn in direction of arrow release pressure on screwdriver to release the fuse Pull cap and fuse out of fuse holder Insert proper fuse into fuse cap Insert fuse cap into fuse holder Using screwdriver rotate fuse cap assembly...

Page 7: ...lass stage plate 80mm 941 460B Black plastic stage plate 80mm 941 460W White plastic stage plate 80mm 941 410 Black White plastic contrast plate 80mm 965 400 05 Eyepiece reticle 5mm 100 div 22 8 mm diameter for WF10x eyepiece only 965 400 10 Eyepiece reticle 10mm 100 div 22 8 mm diameter for WF10x eyepiece only LIMITED LIFETIME WARRANTY Please see our website www nationaloptical com for complete w...