Modes

Intellisense i7 has seven selectable operating modes. The fan 

is set to Mode 1 at the factory, which means that it will 

automatically run at three speeds, see mode description below.

Changing the function

Lift the cover plate. Select the desired mode 

manually with a screwdriver. Ready to go!

It is possible to change mode even when the  

 

motor unit has been removed from the wall frame.

Modes for continuous basic ventilation

Mode 1  Fully automatic, three (3) speeds: 

 

Basic flow - low speed 40 m

3

/h 

 

Presence sensor - medium speed 60 m

3

/h 

 

Humidity control - high speed 95 m

3

/h

Mode 2  As mode 1, but Humidity control at max speed 110 m

3

/h.

Mode 3  Fully automatic, two (2) speeds: 

 

Basic flow - low speed 40 m

3

/h 

 

Humidity control - high speed 95 m

3

/h 

Modes for occasional ventilation needs

(Backdraught shutter optional)

Mode 4  Auto start at motion / light or rising humidity level.    

 

Presence sensor - medium speed 60 m

3

/h  

 

 

(fan starts after a 2.5 minute on-delay). 

 

Humidity control - high speed 95 m

3

/h

Mode 5  Manual start/stop via switch. High speed 95 m

3

/h.

Mode 6  Presence sensor - medium speed 60 m

3

/h  

 

 

Humidity control - high speed 95 m

3

/h    

 

 

Airing function. Auto start if the fan been inactive for  

 

more than 24 hrs. Medium speed 30 min every 12 hrs.

Extra ventilation modes

Mode 8  As mode 3, but Basic flow at medium speed 60 m

3

/h

Mode 9  Only Humidity control, high speed 95 m

3

/h

Heat Mover

Mode 7  Heat mover unit, thermostat. High speed 95 m

3

/h

Mode 0   Not in use

Description of operating modes

Continuous basic ventilation (basic airflow)

The fan operates at a constant low speed, 40 m

3

/h,  

creating a useful basic ventilation. Intellisense i7 has a  

self-calibrating motor that prevents backdraughts.

Presence sensor – motion (IR) and light

The presence sensor is activated by motion (IR) or when 

the lighting is switched on. Over run time 15 minutes. 

The fan switches to a medium speed, 60 m

3

/h, and  

depending on the choice of mode, it starts up:

–  directly (mode 1, 2 and 6)

–   after a 2.5 minute on-delay (mode 4)

Automatic humidity control

A self-adjusting humidity sensor continuously measures 

the humidity level in the room. The fan starts up automat-

ically if the humidity level rises rapidly (e.g. in the case of 

a shower) or if the relative humidity (RH) exceeds 70%. 

When the humidity level is restored, the fan returns to  

the basic flow or stops. 

Depending on the choice of mode, the fan will operate at:

–   High speed 95 m

3

/h (mode 1, 3, 4, 6, 8 and 9)

–   Maximum speed 110 m

3

/h (mode 2)

Manual start and stop by use of a switch

The fan may be connected for manual start via a separate 

light/power switch. When the switch is turned on, the fan 

will start up and run at high speed, 95 m

3

/h. When the 

switch is turned off, the fan will stop.

Airing function

If the humidity control or presence sensor has not been 

active for 24 hours, the airing function will start up. The fan 

will operate at medium speed for 30 minutes every 12 hours. 

Heat Mover, thermostat

The fan will start at 28°C and move the surplus heat to  

adjacent rooms. The fan turns off at 24°C. Airflow 95 m

3

/h.

Summary of Contents for Monsoon Intellisense i7

Page 1: ...Stathe Road Burrowbridge Somerset TA7 0RY Tel 01823 690 290 Email info nvagroup co uk Web www nationalventilation co uk 2 Mounting illustrations 3 Parts 4 7 User and Installation instructions...

Page 2: ...2 PH1 3x 4 5 4 5 PH1 3x off on b 1 a 1 b 2 3 4 a 4 c 5 a 4 b 5 b 5 c 6 c 3x a PH2 3x...

Page 3: ...le cover 5 Presence sensor Motion IR and light 6 Self adjusting humidity control Thermostat 7 Self calibrating motor guarantees correct flow 8 Integrated multi pole switch Package includes 1 pc Intell...

Page 4: ...roved for installation in wet areas IP44 such as WCs bathrooms and utility rooms For mounting on wall or ceiling separate well insulated ventilation duct 80 125 mm Heat Mover save energy Intellisense...

Page 5: ...l frame so that the cable membrane is uppermost 45 Screw the wall frame to the substrate PH2 x3 4 Electrical connection NOTE May only be carried out by qualified electrician During any electrical work...

Page 6: ...eed 95 m3 h Mode 0 Not in use Description of operating modes Continuous basic ventilation basic airflow The fan operates at a constant low speed 40 m3 h creating a useful basic ventilation Intellisens...

Page 7: ...n the fan The fan must not be submerged in or flushed with water Prior to cleaning Turn off power to the fan with the integral multi pole selector Lift the motor unit out of the wall frame see fig 1a...

Page 8: ...ht to material and design changes 497312 Stathe Road Burrowbridge Somerset TA7 0RY Tel 01823 690 290 Email info nvagroup co uk Web www nationalventilation co uk EU Authorised Representative National V...

Reviews: