Installation  

See pictures on page 2, each 

instruction is relative to the alphanumeric naming system 

on images

1. Preparations

The motor unit has a bayonet mount that facilitates  

removal and reassembly during installation, change  

of function and cleaning. 

a)  Lightly grasp the spokes and turn anti-clockwise.

  Lift the motor unit out of the wall frame.

b)  The wall frame cover is retained by 3 screws (PH1).  

  Untighten them and remove the cover. The screws  

  remain in their respective seals  (do not need to be fully  

 unscrewed). 

2. Sealing gaskets

 

To avoid water penetrating the fan, the wall frame has  

several integrated sealing gaskets (If needed, use silicone 

sealant):
a)  on the rear, seal against the substrate. 

b)  by the cable membrane.

c)   by the screw membrane, 3 in total.
  Note: Seal any gaps between fan and ventilation duct. 

3. Mounting the wall frame 

The fan is surface mounted on exterior wall or ceiling.  

Suitable for Ø 100 mm duct (min Ø80– max Ø125).
 

–  The cable membrane is situated in the top part of the

  wall frame. Electrical connection can either be   

  performed from the rear (concealed) or from the  

  top (external). Make a hole in the seal with a suitable  

  sharp tool, see figure 2. 

–  Position the wall frame so that the cable membrane 

  is upp/- 45°.

–   Screw the wall frame to the substrate (PH2 x3).

4. Electrical connection

NOTE! May only be carried out by qualified electrician.

During any electrical work on the fan, the voltage  supply 

must be disconnected.
The fan is designed for permanent installation at    

230V AC, 50Hz. Double-insulated, requires no earth. 
a)  Connect Live & Neutral into the terminal block.
If necessary, the unused Earth cable can be stored in two 

places:

b)  to the right of the terminal board.

c)  to the right of the cable bushing. 

5. Reassemble wall frame cover and motor unit

a)  Reassemble the cover on the wall frame. 

  Be sure that the two 12V pins are in the correct position  

  (rating plate downwards, arrow upwards).
b)  Reassemble and lock the motor unit in the wall frame by

  turning it clockwise. To locate the correct position for the  

  bayonet mount, the ”UP” label on motor unit and wall  

  frame should match. 

  The motor unit is correctly mounted, when the two lines  

  by the multi-pole switch are lined up.

6. Activate the fan – Multi-pole switch

The fan comes with the multi-pole switch to position 0.  

The fan is activated by setting the switch to position 1.
According to the standard for domestic products, EN 60335-

1,  it must be possible to isolate such products from the  

electric power supply. This requirement is met with the  

built-in multi-pole switch (2-pole, 3 mm contact gap). 

Summary of Contents for Monsoon Intellisense i7

Page 1: ...Stathe Road Burrowbridge Somerset TA7 0RY Tel 01823 690 290 Email info nvagroup co uk Web www nationalventilation co uk 2 Mounting illustrations 3 Parts 4 7 User and Installation instructions...

Page 2: ...2 PH1 3x 4 5 4 5 PH1 3x off on b 1 a 1 b 2 3 4 a 4 c 5 a 4 b 5 b 5 c 6 c 3x a PH2 3x...

Page 3: ...le cover 5 Presence sensor Motion IR and light 6 Self adjusting humidity control Thermostat 7 Self calibrating motor guarantees correct flow 8 Integrated multi pole switch Package includes 1 pc Intell...

Page 4: ...roved for installation in wet areas IP44 such as WCs bathrooms and utility rooms For mounting on wall or ceiling separate well insulated ventilation duct 80 125 mm Heat Mover save energy Intellisense...

Page 5: ...l frame so that the cable membrane is uppermost 45 Screw the wall frame to the substrate PH2 x3 4 Electrical connection NOTE May only be carried out by qualified electrician During any electrical work...

Page 6: ...eed 95 m3 h Mode 0 Not in use Description of operating modes Continuous basic ventilation basic airflow The fan operates at a constant low speed 40 m3 h creating a useful basic ventilation Intellisens...

Page 7: ...n the fan The fan must not be submerged in or flushed with water Prior to cleaning Turn off power to the fan with the integral multi pole selector Lift the motor unit out of the wall frame see fig 1a...

Page 8: ...ht to material and design changes 497312 Stathe Road Burrowbridge Somerset TA7 0RY Tel 01823 690 290 Email info nvagroup co uk Web www nationalventilation co uk EU Authorised Representative National V...

Reviews: