Shoppertron
TM
Operator’s Guide
4310114
Page 47
July, 2003
VIEW TIME DATA
1.
Press
, then press
until the display shows
TIME DATA
.
2.
Press
. The following message scrolls across the display:
MAIN.1 237M 01/30 10.13
This example shows the latest time interval the main (monetary) door was
open (1). It was open for 237 minutes, and was opened on January 30 (
01/
30
) at 10:13 am (
10.13
). Press
. If applicable, similar displays will
appear for intervals 2, 3, and 4. Otherwise, go to the next step.
3.
The following message scrolls across the display:
AUX.1 33M 01/30 10.58
This example shows the latest time interval the auxiliary (cold) door was
open (
1
). It was open for 33 minutes (
33M
), and was opened on January 30
(
01/30
) at 10:58 am (
10.58
). Press
. If applicable, similar displays
will appear for intervals 6, 7, and 8. Otherwise, go to the next step.
4.
The following message scrolls across the display:
HC.ER 01/30 14.09 MAX. 69
O
F
This example shows that the health control timer turned off on January 30
(
01/30
) at 2:09 pm (
14.09
), and the maximum temperature reached was 69°F.
NOTE
The temperature display units will be in
o
C if you selected Cel-
sius during the temperature display function.
5.
Press
. The following message scrolls across the display:
LAST POWER 01/30 13.51 FOR 00. 0.23
This example shows that the last time the machine lost power was on Janu-
ary 30 (
01/30
) at 1:51pm (
13.51
) for zero days, zero hours, and 23 minutes
(
00. 0.23
).
6.
Press
. The following message scrolls across the display:
LONGS.T POWER 01/30 10.58 FOR 00. 2.47
This example shows that the longest time the machine was without power
was on January 30 (
01/30
) at 10:58am (
10.58
) for zero days, 2 hours and 47
minutes (
00. 2.47
).
Summary of Contents for shoppertron 431
Page 1: ......
Page 70: ...ShoppertronTM Operator s Guide July 2003 Page 66 4310114 ...
Page 74: ......