1
Low voltage. This is shown when the DC supply voltage is low. The battery could be
flat, wiring losses are too high or there is a poor connection to the power source.
2
Fan over-current cut-out. There is a problem with the ventilation fan. It is possible that
the ventilation fan is damaged.
3
Motor start error. The compressor has not started successfully. This can happen in
extreme environments where the refrigerator is heavily loaded & temperature is very high.
4
Minimum speed error. The motor cannot maintain a minimum speed of 1900 rpm.
This can be the result of an Electronic Compressor Driver failure.
5
Thermal cut-out. The electronic circuitry has over-heated. This happens in very hot
environments. This can occur when the fridge is over-loaded with warm contents and
the ambient temperature is high. The electronics will re-set when the temperature
has dropped.
6
Electronic Compressor Driver hardware failure.
NUMBER
OF
FLASHES
FAULT DESCRIPTION
iiiiiii
i
iiiiii
ii
iiiiiii
i
iiiiii
ii
iiiiiii
i
iiiiii
ii
iiiiiii
i
iiiiii
ii
iiiiiii
i
iiiiii
ii
iiiiiii
i
iiiiii
ii
Trouble Shooting
Indicator Lights
Status indicators will identify the current operation of the refrigerator.
RUN -
This indicator will be illuminated whenever the fridge Compressor is running and the
compartment is being cooled.
The Compressor is running.
½ second on, ½ second off... Compressor start up delay. There is a 1 minute delay
before the compressor starts
1 second on, 1 second off... Compressor slow down cycle.The Compressor slows
down to low speed before stopping (30 seconds)
FAULT ID -
This indicator is used to identify fault conditions that may occur with the refrigerator
such as low power supply. This indicator will flash a pre-determined number of times
every 4 seconds when a particular fault occurs.
iiiiiii
i
iiiiii
ii
iiiiiii
i
iiiiii
ii
iiiiiii
i
iiiiii
ii
SOLID -
FLASH -
FLASH -