Touchscreen Configuration
This appendix explains how to configure the PPC-2115/TPC-2515
touchscreen using the PenMount Control Panel.
Touchscreen Calibration
Click the
pm
icon in the lower right corner of the screen to access the
PenMount Control Panel. The panel contains five functions: Calibrate,
Draw, and Option, all described below, Multiple Monitors, and About.
Multiple Monitors is for calibrating multiple touchscreen displays only;
it does not apply to the PPC-2115/TPC-2515, which allows only one
touchscreen display. About shows the driver version.
Calibrate
There are two ways to calibrate the touchscreen—standard calibration and
advanced calibration.
Use standard calibration to adjust newer touchscreens, which need only a
few calibration points. Follow these steps to use standard calibration:
1.
Click the
Standard Calibration
button on the
Calibrate
tab of the
PenMount Control Panel.
2.
A screen with a small red square appears. Touch the red square on this
screen and the screens that follow it.
3.
The calibration is complete after you touch the red square on the
fifth screen.
Note
Press <ESC> to skip any calibration screen.