SCXI-1356 Shielded Cable Installation Guide
12
ni.com
Note
Pins 1 through 9 and pins 35 through 43 on the 68-pin connector of the
ACH16–ACH68 branch of the SCXI-1356 are not connected.
Specifications
Maximum Working Voltage
Maximum working voltage refers to the signal voltage plus the
common-mode voltage.
Channel-to-earth .....................................250 V, installation category II
Channel-to-channel.................................250 V, installation category II
ACH48
A6
17
35
ACH56
C5
51
36
ACH49
B5
16
37
ACH57
A5
50
38
ACH50
C4
49
39
ACH58
B4
15
40
ACH51
A4
14
41
ACH59
C3
48
42
ACH52
B3
13
43
ACH60
A3
47
44
ACH53
C2
46
45
ACH61
B2
12
46
ACH54
A2
11
47
ACH62
C1
45
48
ACH55
B1
10
49
ACH63
A1
44
50
* SENSE for ACH16–ACH63
Table 2.
Cable Connections for the ACH16
–
ACH63 Branch (Continued)
Signal Names
Connector Pin Numbers
96-Pin
68-Pin
50-Pin