Environment
Operating temperature ............................0 to 50 °C
Storage temperature ................................–20 to 70 °C
Relative humidity ...................................5% to 90% noncondensing
Safety
Designed in accordance with IEC 61010-1, UL 3111-1, and CAN/CSA
C22.2 No. 1010.1 for electrical measuring and test equipment.
Approved at altitudes up to 2000 meters.
Installation Category II
Pollution Degree 2
Temperature Sensor Circuit Diagram
The circuit diagram in Figure 6 is optional information that you can use if
you want more details about the SCXI-1322 temperature sensor.
Figure 6.
Temperature Sensor Circuit Diagram
4.7 k
Ω
1%
5 k
Ω
0.1%
MTEMP
1
2
1
2
2
+
5 k
Ω
at 25
o
C
10
µ
F
16 V
0.1
µ
F
0.1
µ
F
-t
o
+5 V
2.5 V
LM 4040
2.5 V
0.1%
Summary of Contents for SCXI-1322