Chapter 2
Configuration and Installation
2-12
ni.com
After selecting the excitation mode of operation desired—Voltage or
Current—as described in the previous section, use Table 2-8 to set your
SCXI-1121 for the level of operation. Your SCXI-1121 is shipped with the
Voltage mode set to 3.333 V.
0.150 mA
10 k
Ω
0.450 mA
10 k
Ω
Table 2-8.
Excitation Level Jumper Selection
Excitation
Channel
Jumpers
3.333 V or 0.150 mA
(Factory Setting)
10 V or 0.450 mA
0
W16 and W26
1
W24 and W25
2
W36 and W37
3
W48 and W49