National Instruments SCC-CTR01 User Manual And Specifications Download Page 5

©

 National Instruments Corporation

5

NI SCC-CTR01 User Guide and Specifications

Measurement Studio

If you program your NI-DAQmx-supported device in Measurement Studio 
using Visual C++, Visual C#, or Visual Basic .NET, you can interactively 
create channels and tasks by launching the DAQ Assistant from MAX or 
from within Visual Studio .NET. You can generate the configuration code 
based on your task or channel in Measurement Studio. Refer to the 

DAQ 

Assistant Help

 for additional information about generating code. You also 

can create channels and tasks, and write your own applications in your 
ADE using the NI-DAQmx API.

For help with NI-DAQmx methods and properties, refer to the NI-DAQmx 
.NET Class Library or the NI-DAQmx Visual C++ Class Library included 
in the 

NI Measurement Studio Help

. For general help with programming in 

Measurement Studio, refer to the 

NI Measurement Studio Help

, which is 

fully integrated with the Microsoft Visual Studio .NET help. To view 
this help file in Visual Studio. NET, select 

Measurement Studio»

NI Measurement Studio Help

.

To create an application in Visual C++, Visual C#, or Visual Basic .NET, 
follow these general steps:

1.

In Visual Studio .NET, select 

File»New»Project

 to launch the New 

Project dialog box.

2.

Find the Measurement Studio folder for the language you want to 
create a program in.

3.

Choose a project type. You add DAQ tasks as a part of this step.

ANSI C without NI Application Software

The 

NI-DAQmx Help

 contains API overviews and general information 

about measurement concepts. Select 

Start»All Programs»National 

Instruments»NI-DAQ»NI-DAQmx Help

.

The 

NI-DAQmx C Reference Help

 describes the NI-DAQmx Library 

functions, which you can use with National Instruments data acquisition 
devices to develop instrumentation, acquisition, and control applications. 
Select 

Start»All Programs»NationalInstruments»NI-DAQ»

NI-DAQmx C Reference Help

.

.NET Languages without NI Application Software

With the Microsoft .NET Framework version 1.1 or later, you can use 
NI-DAQmx to create applications using Visual C# and Visual Basic .NET 
without Measurement Studio. You need Microsoft Visual Studio 
.NET 2003 or Microsoft Visual Studio 2005 for the API documentation to 
be installed.

Summary of Contents for SCC-CTR01

Page 1: ...The sequence File Page Setup Options directs you to pull down the File menu select the Page Setup item and select Options from the last dialog box This icon denotes a caution which advises you of prec...

Page 2: ...C 2345 connector block and the NI SC 2345 with configurable connectors SCC SCC refers to any SCC Series signal conditioning module What You Need to Get Started To set up and use the NI SCC CTR01 you n...

Page 3: ...All Programs National Instruments NI DAQ DAQ Getting Started Guide The NI DAQ Readme lists which devices are supported by this version of NI DAQ Select Start All Programs National Instruments NI DAQ...

Page 4: ...s and tools Refer to the following locations on the Contents tab of the LabVIEW Help for information about NI DAQmx Getting Started Getting Started with DAQ Includes overview information and a tutoria...

Page 5: ...select Measurement Studio NI Measurement Studio Help To create an application in Visual C Visual C or Visual Basic NET follow these general steps 1 In Visual Studio NET select File New Project to laun...

Page 6: ...he Filtered By drop down list and follow the previous instructions Device Documentation and Specifications NI DAQmx includes the Device Document Browser which contains online documentation for support...

Page 7: ...re Device Specific Information Note For general SCC module installation and signal connection information and information about the NI SC 2345 carrier refer to the SCC Quick Start Guide available for...

Page 8: ...gnals Figure 1 illustrates a single isolated input Figure 1 Single Isolated Input Inputs are referenced to either the ground or supply of the external device depending on whether or not the external d...

Page 9: ...connect the NI SCC CTR01 as referenced to ground and as referenced to the supply Connecting the NI SCC CTR01 as Referenced to Ground Connect the external device to the SRC or GATE pin and connect the...

Page 10: ...TTL devices reference the NI SCC CTR01 to the supply as shown in Figure 3 Note When placing a relatively slow rise time signal such as a 5 V peak sine or triangle wave on one of the inputs and a fast...

Page 11: ...in the Specifications section If the amount of current the MOSFET conducts exceeds a certain level 800 mA typical such as when a short occurs in the load the MOSFET turns off for 250 ms to protect it...

Page 12: ...switch the MOSFET to OFF Driving Inductive Loads Caution When the output of the NI SCC CTR01 is used to drive an inductive load high voltages will appear suddenly because of the current switching thr...

Page 13: ...the NI SCC CTR01 and other equipment In addition the NI SCC CTR01 is equipped with overvoltage protection and can handle continuous voltages between the and input terminals up to 60 VDC Frequencies o...

Page 14: ...if the output current exceeds a certain limit 800 mA typical 1 1 A max The NI SCC CTR01 tries to reoperate every 250 ms and automatically recovers after the short is removed Reverse and Overvoltage Pr...

Page 15: ...by the following equation for a positive pulse in positive logic Example If using typical LOW to HIGH and HIGH to LOW propagation delays relays 180 ns and 150 ns and the actual measured pulse width is...

Page 16: ...nce to either supply or ground two terminals per input Maximum input frequency 400 kHz Minimum input pulse width 1 s Input to input input to output and input to PC ground isolation 60 VDC continuous v...

Page 17: ...e switch Output power requirement 5 to 48 VDC 10 mA per channel typical at 400 kHz Load voltage range 5 to 48 VDC Switching current 100 mA max Inrush current 600 mA max Maximum output frequency 400 kH...

Page 18: ...male connector one 7 pin screw terminal Field wiring diameter 28 to 16 AWG Environmental Operating temperature 0 to 50 C Storage temperature 20 to 70 C Humidity 10 to 90 RH noncondensing Maximum altit...

Page 19: ...by model number or product line and click the appropriate link in the Certification column Environmental Management National Instruments is committed to designing and manufacturing products in an env...

Page 20: ...de and Specifications 20 ni com NI SCC SCTRO1 Module Pin Assignments Figure 6 shows the I O connector on the bottom of the NI SCC CTR01 Figure 6 SCC Module Bottom View 1 Pin 1 2 Pin 2 3 PWB Key 4 Pin...

Page 21: ...s products refer to the appropriate location Help Patents in your software the patents txt file on your CD or ni com patents 2005 2007 National Instruments Corporation All rights reserved 371673B 01 D...

Reviews: