National Instruments Corporation
19
NI RMC-8354 Installation Guide
8 GB memory upgrade (64-bit OS)........ 4
×
2 GB (128 M
×
72 bit),
DDR-III SDRAM, ECC
1333 MHz
16 GB memory upgrade (64-bit OS)...... 4
×
4 GB (512 M
×
72 bit),
DDR-III SDRAM, ECC
1333 MHz
Mechanical
Overall dimensions (standard chassis)
Height.............................................. 1U
Width .............................................. 437 mm (17.2 in.)
Depth............................................... 503 mm (19.8 in.)
Weight (with four 500 GB drives) ......... 10.75 kg (23.7 lbs)
Environmental
Caution
If installed in a closed or multiunit rack assembly, the rack environment operating
ambient temperature may be greater than room ambient temperature. Therefore, install the
equipment in an environment compatible with the maximum ambient temperature (Tma)
the manufacturer specifies.
Operating temperature............................ 5 to 35 °C
(Tested in accordance
with IEC-60068-2-1.)
Storage temperature ............................... –40 to 70 °C
(Tested in accordance
with IEC-60068-2-1 and
IEC-60068-2-2.)
Relative humidity (tested in accordance with IEC-60068-2-56)
Operating ........................................ 10 to 90% noncondensing
Nonoperational (storage) ................ 5 to 95% noncondensing
Installation Category .............................. II
Pollution Degree .................................... 2
Altitude................................................... 2,000 m
Operating location.................................. Indoor use only