SCC-RLY01 Relay Module User Guide

Power Requirement

Digital power.......................................... 300 mW max

+5 V........................................................ 60 mA max

Physical

Dimensions............................................. 8.89 cm 

× 

2.92 cm 

×

 1.85 cm

(3.50 in. 

×

 1.15 in. 

×

 0.73 in.)

Mass ....................................................... 37 g (1.3 oz)

I/O connectors ........................................ One 20-pin right-angle 

male connector
One 3-pin screw-terminal block

Field-wiring diameter............................. 28 to 16 AWG

Maximum Working Voltage

Maximum working voltage refers to the signal voltage plus the 
common-mode voltage.

Channel to earth (inputs)

........................ ±

300 V, Installation Category II

1

Environmental

Operating temperature............................ 0 to 50 °C

Storage temperature ............................... –20 to 65 °C

Humidity ................................................ 10 to 90% RH, noncondensing

Maximum altitude .................................. 2,000 m

Pollution Degree (indoor use only) ........ 2

Safety

The SCC-RLY01 meets the requirements of the following standards 
for safety of electrical equipment for measurement, control, and 
laboratory use:

IEC 61010-1, EN 61010-1

UL 3111-1, UL 61010B-1

CAN/CSA C22.2 No. 1010.1

1   

Isolation test voltage is 2,400 VAC at 2 s.

Summary of Contents for Relay Module SCC-RLY01

Page 1: ...ted with a bit or signal name for example P0 3 0 The symbol leads you through nested menu items and dialog box options to a final action The sequence File Page Setup Options directs you to pull down t...

Page 2: ...ams subroutines device names functions operations variables filenames and extensions SC 2345 SC 2345 refers to both the SC 2345 connector block and SC 2345 with configurable connectors SCC SCC refers...

Page 3: ...o the Read Me First Safety and Radio Frequency Interference document before removing equipment covers or connecting disconnecting any signal wires Plug the SCC RLY01 into any P0 socket J X 9 where X i...

Page 4: ...al Contact type SPDT Form C nonlatching Nominal switching capacity 5 A at 250 VAC 5 A at 30 VDC Signal bandwidth DC to 400 Hz Contact resistance 30 m max Switching time Operate time NC to NO 5 ms 10 m...

Page 5: ...orking voltage refers to the signal voltage plus the common mode voltage Channel to earth inputs 300 V Installation Category II1 Environmental Operating temperature 0 to 50 C Storage temperature 20 to...

Page 6: ...15 Class A Compliant Note For full EMC compliance operate this device with shielded cabling CE Compliance This product meets the essential requirements of applicable European Directives as amended for...

Page 7: ...nnector pins on the bottom of the module Figure 1 SCC Module Bottom View Table 1 lists the signal connection corresponding to each pin GND is the reference for the 5 V supply 1 Pin 1 2 Pin 2 3 PWB Key...

Page 8: ...their respective companies For patents covering National Instruments products refer to the appropriate location Help Patents in your software the patents txt file on your CD or ni com patents 2001 200...

Reviews: