National Instruments Relay Module SCC-RLY01 User Manual Download Page 3

©

 National Instruments Corporation

3

SCC-RLY01 Relay Module User Guide

Wire insulation strippers

NI-DAQ (current version) for Windows 2000/NT/XP

Note

Configuring the SCC system using Measurement & Automation Explorer (MAX) is 

not supported on the Macintosh operating system.

Device Specific Information

Note

For general SCC module installation and signal connection information, and 

information about the SC-2350 carrier, refer to the 

SCC Quick Start Guide

, available 

for download at 

ni.com/manuals

.

Installing the Module

Caution

Refer to the 

Read Me First: Safety and Radio-Frequency Interference

 document 

before removing equipment covers or connecting/disconnecting any signal wires.

Plug the SCC-RLY01 into any P0. socket J(

X

+

9), where 

X

 is 0 to 7, on the 

SC-2345.

Connecting the Input Signals

Note

The signal names have changed. Refer to 

ni.com/info

 and enter 

rdtntg

 

to confirm the signal names.

Each screw terminal is labeled by pin number <1..3>. Pin 1 is the NC 
terminal, pin 2 is the COM terminal, and pin 3 is the NO terminal.

The SCC-RLY01 contains one SPDT relay controlled by an E Series DAQ 
device P0. line 

X

. The value of 

X

 is determined by the number of the P0. 

socket, J(

X

+

9), where you plug in the SCC-RLY01. The following figure is 

a circuit diagram of the SCC-RLY01.

Summary of Contents for Relay Module SCC-RLY01

Page 1: ...ted with a bit or signal name for example P0 3 0 The symbol leads you through nested menu items and dialog box options to a final action The sequence File Page Setup Options directs you to pull down t...

Page 2: ...ams subroutines device names functions operations variables filenames and extensions SC 2345 SC 2345 refers to both the SC 2345 connector block and SC 2345 with configurable connectors SCC SCC refers...

Page 3: ...o the Read Me First Safety and Radio Frequency Interference document before removing equipment covers or connecting disconnecting any signal wires Plug the SCC RLY01 into any P0 socket J X 9 where X i...

Page 4: ...al Contact type SPDT Form C nonlatching Nominal switching capacity 5 A at 250 VAC 5 A at 30 VDC Signal bandwidth DC to 400 Hz Contact resistance 30 m max Switching time Operate time NC to NO 5 ms 10 m...

Page 5: ...orking voltage refers to the signal voltage plus the common mode voltage Channel to earth inputs 300 V Installation Category II1 Environmental Operating temperature 0 to 50 C Storage temperature 20 to...

Page 6: ...15 Class A Compliant Note For full EMC compliance operate this device with shielded cabling CE Compliance This product meets the essential requirements of applicable European Directives as amended for...

Page 7: ...nnector pins on the bottom of the module Figure 1 SCC Module Bottom View Table 1 lists the signal connection corresponding to each pin GND is the reference for the 5 V supply 1 Pin 1 2 Pin 2 3 PWB Key...

Page 8: ...their respective companies For patents covering National Instruments products refer to the appropriate location Help Patents in your software the patents txt file on your CD or ni com patents 2001 200...