National Instruments PXIe-8830mc User Manual Download Page 16

Table 3.

 USB 2.0 Connector Signals (Continued)

Pin

Signal Name

Signal Description

 

 

 

3

+Data

USB Data +

4

GND

Ground

Worldwide Support and Services

The National Instruments website is your complete resource for technical support. At 

ni.com/

support

, you have access to everything from troubleshooting and application development

self-help resources to email and phone assistance from NI Application Engineers.

Visit 

ni.com/services

 for NI Factory Installation Services, repairs, extended warranty, and

other services.

Visit 

ni.com/register

 to register your National Instruments product. Product registration

facilitates technical support and ensures that you receive important information updates from
NI.

A Declaration of Conformity (DoC) is our claim of compliance with the Council of the
European Communities using the manufacturer’s declaration of conformity. This system
affords the user protection for electromagnetic compatibility (EMC) and product safety. You
can obtain the DoC for your product by visiting 

ni.com/certification

. If your product supports

calibration, you can obtain the calibration certificate for your product at 

ni.com/calibration

.

National Instruments corporate headquarters is located at 11500 North Mopac Expressway,
Austin, Texas, 78759-3504. National Instruments also has offices located around the world.
For telephone support in the United States, create your service request at 

ni.com/support

 or

dial 1 866 ASK MYNI (275 6964). For telephone support outside the United States, visit the

Worldwide Offices

 section of 

ni.com/niglobal

 to access the branch office websites, which

provide up-to-date contact information, support phone numbers, email addresses, and current
events.

Refer to the 

NI Trademarks and Logo Guidelines

 at 

ni.com/trademarks

 for information on National Instruments trademarks.

Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents
covering National Instruments products/technology, refer to the appropriate location: 

Help

»

Patents

 in your software, the

patents.txt

 file on your media, or the 

National Instruments Patent Notice

 at 

ni.com/patents

. You can find information about

end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the 

Export

Compliance Information

 at 

ni.com/legal/export-compliance

 for the National Instruments global trade compliance policy and

how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES
AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS.
U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the
applicable limited rights and restricted data rights as set forth in FAR 52.227-14, DFAR 252.227-7014, and DFAR 252.227-7015.

© National Instruments. All rights reserved.

374587A-01

Aug14

Summary of Contents for PXIe-8830mc

Page 1: ...x A Front Panel Connector Pinouts 13 Ethernet 13 Universal Serial Bus 15 Worldwide Support and Services 16 Electromagnetic Compatibility Guidelines This product was tested and complies with the regula...

Page 2: ...1 0 PXI Express Features Benefits of PXI Express The PXI PCI eXtensions for Instrumentation industry standard an open specification governed by the PXI Systems Alliance PXISA has quickly gained adopti...

Page 3: ...system reference clock for the synchronization of multiple modules and three differential star trigger buses for the distribution of precise clock and trigger signals have been added Differential timi...

Page 4: ...ogic block that is the NI PXIe 8830mc The system on the left is designated the primary system host which serves as the central connection hub for all other PXImc devices Refer to the NI PXImc Help and...

Page 5: ...s of one 64 bit DDR3L SDRAM socket that can hold up to 8 GB of memory The Platform Controller Hub PCH provides the USB PCI Express x1 and LPC interfaces that connect to the peripherals on the NI PXIe...

Page 6: ...t or interactive environment such as NI Signal Express These functions provide an intuitive API for National Instruments multifunction DAQ products Features available include analog input A D conversi...

Page 7: ...n create Virtual Instruments based on the Linux OS The NI VISA driver for Linux has improved instrument control in Linux and NI Modular Instruments are partially supported For more information visit n...

Page 8: ...module on the side of the processor module as shown in the figure 3 Remove the installed DDR3 SO DIMM module if necessary 4 Install the new DDR3 SO DIMM module into the slot NI PXIe 8830mc System Memo...

Page 9: ...1 2 1 DDR3 SO DIMM Module 2 DDR3 SO DIMM Socket Specifications This section lists the system specifications for the following product only NI PXIe 8830mc 156252x 011L Note The NI assembly number in pa...

Page 10: ...5 NI PXIe 8830mc Front Panel Dimensions 5 067 in 128 70 mm 3 750 in 95 24 mm 1 572 in 39 93 mm 1 064 in 27 02 mm 0 000 in 0 00 mm 0 372 in 9 45 mm 0 707 in 17 96 mm 1 588 in 40 34 mm 0 000 in 0 00 mm...

Page 11: ...eets MIL PRF 28800F Class 3 low temperature limit and MIL PRF 28800F Class 2 high temperature limit Relative humidity range 10 to 90 noncondensing Tested in accordance with IEC 60068 2 56 Storage Envi...

Page 12: ...Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement control and laboratory use EN 61326 1 IEC 61326 1 Class A emissions Basic immu...

Page 13: ...b page at ni com environment This page contains the environmental regulations and directives with which NI complies as well as other environmental information not included in this document Waste Elect...

Page 14: ...TX TX_A 3 RX RX_B 4 NC TX_C 5 NC TX_C 6 RX RX_B 7 NC RX_D 8 NC RX_D Note The Ethernet processor module can perform an automatic crossover thus eliminating the need for crossover cables Table 2 10 100...

Page 15: ...is selected Universal Serial Bus The following figure shows the location and pinouts for the Universal Serial Bus USB connector on the NI PXIe 8830mc Each processor module has two USB ports on the fr...

Page 16: ...es create your service request at ni com support or dial 1 866 ASK MYNI 275 6964 For telephone support outside the United States visit the Worldwide Offices section of ni com niglobal to access the br...

Reviews: