Environmental

Maximum altitude

2,000 m (800 mbar) (at 25 °C ambient)

Pollution Degree

2

Indoor use only.

Operating Environment

Ambient temperature range

Passive cable

0 °C to 55 °C (Tested in accordance with
IEC-60068-2-1 and IEC-60068-2-2. Meets
MIL-PRF-28800F Class 3 low temperature
limit and MIL-PRF-28800F Class 2 high
temperature limit.)

Active cable

10 °C to 35 °C (Tested in accordance with
IEC-60068-2-1 and IEC-60068-2-2. Meets
MIL-PRF-28800F Class 4 low temperature
limit.)

Relative humidity range

10% to 90%, noncondensing (Tested in
accordance with IEC-60068-2-56.)

Storage Environment

Ambient temperature range

-40 °C to 71 °C (Tested in accordance with
IEC-60068-2-1 and IEC-60068-2-2. Meets
MIL-PRF-28800F Class 3 limits.)

Relative humidity range

5% to 95%, noncondensing (Tested in
accordance with IEC-60068-2-56.)

Note

 

Clean the PXIe-8301 with a soft nonmetallic brush. Make sure that the device

is completely dry and free from contaminants before returning it to service.

10

  | 

ni.com

  | 

PXIe-8301 User Manual

Summary of Contents for PXIe-8301

Page 1: ...4 Backwards Compatibility 4 Installation and Configuration 4 Equipment Needed 4 Unpacking 4 Hardware Installation 5 Installing a PXIe 8301 5 Cabling 6 Powering On the MXI Express Thunderbolt System 7...

Page 2: ...ss functionality such as chassis and controller identification trigger routing and slot detection install the latest version of PXI Platform Services This software is included with your kit you also c...

Page 3: ...f a PXI Express chassis as shown in the following figure Figure 2 Example of a Basic MXI Express Thunderbolt Link Topology Thunderbolt Bus Extension You can daisy chain from a PXI Express chassis cont...

Page 4: ...h previous generation Thunderbolt ports Data throughput performance may vary between Thunderbolt generations Installation and Configuration This section explains how to unpack install and configure th...

Page 5: ...d to install the PXIe 8301 3 Touch a metal part of the chassis to discharge any static electricity that might be on your clothes or body 4 Make sure the injector ejector handle is in its downward posi...

Page 6: ...erbolt cable to the host PC Thunderbolt port and MXI Express Thunderbolt card The cables have no polarity so you can connect either end to either card The cable plugs are reversible and there is no de...

Page 7: ...Amber Power is within spec no link to chassis Solid Green Power is within spec link established Software Installation and Configuration MXI Express Thunderbolt is based on PCI Express technology using...

Page 8: ...e PXIe 8301 requires your host PC to have a Thunderbolt 3 port How is Thunderbolt 3 different from USB Type C Although Thunderbolt 3 uses the same physical USB Type C connector it is a superset soluti...

Page 9: ...rm Services you can still use MXI Express Thunderbolt as a PCI Express expansion solution However access to features such as chassis and controller identification trigger routing and slot detection wi...

Page 10: ...8 2 1 and IEC 60068 2 2 Meets MIL PRF 28800F Class 4 low temperature limit Relative humidity range 10 to 90 noncondensing Tested in accordance with IEC 60068 2 56 Storage Environment Ambient temperatu...

Page 11: ...EMC standards for electrical equipment for measurement control and laboratory use EN 61326 1 IEC 61326 1 Class A emissions Basic immunity EN 55011 CISPR 11 Group 1 Class A emissions AS NZS CISPR 11 Gr...

Page 12: ...ycle NI products in your region visit ni com environment weee RoHS National Instruments RoHS National Instruments RoHS ni com environment rohs_china For information about China RoHS compliance go to n...

Reviews: