background image

added to the CompactPCI mechanical specification to ease system integration and ensure
multivendor interoperability.

The demanding timing and synchronization requirements of instrumentation systems are met
by the integrated features of PXI Express. Not only are the trigger bus, 10 MHz system
reference clock, and star trigger bus available in PXI retained by PXI Express, but new timing
and synchronization features that include a 100 MHz differential system reference clock for
the synchronization of multiple modules and three differential star trigger buses for the
distribution of precise clock and trigger signals have been added. Differential timing and
synchronization signals provide PXI Express systems with increased noise immunity and the
ability to transmit clock signals at higher frequencies.

PXIe-8240 Overview

Functional Overview

The PXIe-8240 is a peripheral module that provides up to 40 Gigabit Ethernet (GbE)
connectivity on two QSFP+ ports for a PXI Express system. It can attach to a PXI Express
system via a high-bandwidth, low-latency PXI Express backplane Gen3 x8 link.

With the 40Gb Ethernet, it allows offloading data from a PXI Express system to an external
storage solution or a server for further analysis. It also allows data exchange and aggregation
across two or more PXI Express systems.

Functional Description

The PXIe-8240 is a peripheral module in a 1-slot 3U PXI Express form factor. The following
figure is a functional block diagram of the PXIe-8240. Following the diagram is a description
of each logic block shown.

Figure 1. PXIe-8240 Block Diagram

PXI Express

PCI Express

Switch

NI ASIC

Ethernet

Controller

QSFP+

Connector

QSFP+

Connector

x8

x8

x1

OCP Mezzanine Card

The PXIe-8240 consists of the following logic blocks on two circuit card assemblies (CCA):

The 

PXI Express Connectors

 connect the PXIe-8240 to the PXI Express/CompactPCI

Express backplane.

The 

PCI Express Switch

 links the PXI Express backplane to the Ethernet controller on the

OCP mezzanine card with PCI Express x8 links.

The 

OCP Mezzanine Card

 block consists of the Ethernet controller and the QSFP+

connectors that provide the 40 GbE connectivity.

PXIe-8240 User Manual

  | 

© National Instruments

  | 

3

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Summary of Contents for PXIe-8240

Page 1: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...

Page 2: ...stated in the product specifications These requirements and limits provide reasonable protection against harmful interference when the product is operated in the intended operational electromagnetic environment This product is intended for use in industrial locations However harmful interference may occur in some installations when the product is connected to a peripheral device or test object or ...

Page 3: ...dwidth by evolving PCI to PCI Express PXI is now able to meet even more application needs by integrating PCI Express into the PXI standard By taking advantage of PCI Express technology in the backplane PXI Express increases the available PXI bandwidth from up to 132 MB s to up to 8 GB s for a more than 60x improvement in bandwidth PXI Express maximizes both hardware and software compatibility with...

Page 4: ...h low latency PXI Express backplane Gen3 x8 link With the 40Gb Ethernet it allows offloading data from a PXI Express system to an external storage solution or a server for further analysis It also allows data exchange and aggregation across two or more PXI Express systems Functional Description The PXIe 8240 is a peripheral module in a 1 slot 3U PXI Express form factor The following figure is a fu...

Page 5: ...ment for building your test program logic and a collection of automated code generation tools as well as utilities for building automated test systems monitoring applications or laboratory experiments For more information visit ni com lwcvi NI DAQmx provides an extensive library of functions you can call from your application development environment or interactive environment such as NI Signal Exp...

Page 6: ...s on Linux with the NI DAQmx driver you now can create Virtual Instruments based on the Linux OS The NI VISA driver for Linux has improved instrument control in Linux and NI Modular Instruments are partially supported For more information visit ni com linux Specifications This document lists the electrical mechanical and environmental specifications of the PXIe 8240 dual port 40 Gigabit Ethernet p...

Page 7: ...5 51 mm NI PXIe 8240 Electrical Power Rail Typical Value Max Value 3 3 VDC 0 64 A 0 96 A 12 VDC 1 1 A 1 65 A Total Power 15 31 W 22 97 W Physical Board dimensions 1 slot 3U PXI Express peripheral module Compatibility Fully compatible with PXI Express Specification 1 0 Weight 246 2 g 0 54 lb typical 6 ni com PXIe 8240 User Manual Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SO...

Page 8: ...bient temperature range 40 C to 71 C Tested in accordance with IEC 60068 2 1 and IEC 60068 2 2 Relative humidity range 5 to 95 noncondensing Tested in accordance with IEC 60068 2 56 Shock and Vibration Operating shock 30 g peak half sine 11 ms pulse Tested in accordance with IEC 60068 2 27 Meets MIL PRF 28800F Class 2 limits Random vibration Operating 5 Hz to 500 Hz 0 3 grms Nonoperating 5 Hz to 5...

Page 9: ... commercial light industrial and heavy industrial locations In Europe Canada Australia and New Zealand per CISPR 11 Class A equipment is intended for use only in heavy industrial locations Note Group 1 equipment per CISPR 11 is any industrial scientific or medical equipment that does not intentionally generate radio frequency energy for the treatment of material or inspection analysis purposes Not...

Page 10: ...o recycle NI products in your region visit ni com environment weee Battery Replacement and Disposal Cd Hg Pb Battery Directive This device contains a long life coin cell battery If you need to replace it use the Return Material Authorization RMA process or contact an authorized National Instruments service representative For more information about compliance with the EU Battery Directive 2006 66 E...

Page 11: ...elL GND Tx4p Rx4n GND Tx2p Tx2n GND Table 1 QSFP Connector Signals Pin Symbol Name Description 1 GND Ground 2 Tx2n Transmitter Inverted Data Input 3 Tx2p Transmitter Non Inverted Data Input 4 GND Ground 5 Tx4n Transmitter Inverted Data Input 6 Tx4p Transmitter Non Inverted Data Input 7 GND Ground 8 ModSelL Module Select 9 ResetL Module Reset 10 Vcc Rx 3 3V Power Supply Receiver 10 ni com PXIe 8240...

Page 12: ...n Receiver Inverted Data Output 22 Rx2p Receiver Non Inverted Data Output 23 GND Ground 24 Rx4n Receiver Inverted Data Output 25 Rx4p Receiver Non Inverted Data Output 26 GND Ground 27 ModPrsL Module Present 28 IntL Interrupt 29 Vcc Tx 3 3V Power Supply Transmitter 30 Vcc1 3 3V Power Supply 31 LPMode Low Power Mode 32 GND Ground 33 Tx3p Transmitter Non Inverted Data Input 34 Tx3n Transmitter Inver...

Page 13: ... to register your NI product Product registration facilitates technical support and ensures that you receive important information updates from NI A Declaration of Conformity DoC is our claim of compliance with the Council of the European Communities using the manufacturer s declaration of conformity This system affords the user protection for electromagnetic compatibility EMC and product safety Y...

Page 14: ...tes which provide up to date contact information support phone numbers email addresses and current events PXIe 8240 User Manual National Instruments 13 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 15: ...he readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and how to obtain relevant HTS codes ECCNs and other import export data NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS U S Government Customers The data cont...

Page 16: ...l service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment before purchasing with our interactive website at www instraview com LOOKING FOR MORE INFORMATION Visit us on the web at www artisantg com for more information on ...

Reviews: