TB-2705 PXI Terminal Block

SCANCLK

DGND

Output

Scan Clock—This terminal pulses 
once for each A/D conversion in the 
scanning modes when enabled. The 
low-to-high edge indicates when you 
can remove the input signal from the 
input or switched to another signal.

EXTSTROBE

DGND

Output

External Strobe—This output is used 
for controlling SCXI modules. 

PFI0/TRIG1

DGND

Input

PFI0/Trigger 1—As an input, this 
is either one of the programmable 
function inputs (PFIs) or the source for 
the hardware analog trigger. For more 
information on PFI signals, see the 

PXI E Series User Manual

.

Output

As an output, this is the TRIG1 signal. 
In posttrigger data acquisition 
sequences, a low-to-high transition 
indicates the initiation of the 
acquisition sequence. In pretrigger 
applications, a low-to-high transition 
indicates the initiation of the pretrigger 
conversions.

PFI1/TRIG2

DGND

Input

PFI1/Trigger 2—As an input, this is 
one of the PFIs.

Output

As an output, this is the TRIG2 signal. 
In pretrigger applications, a 
low-to-high transition indicates the 
initiation of the posttrigger 
conversions. TRIG2 is not used in 
posttrigger applications.

PFI2/CONVERT

DGND

Input

PFI2/Convert—As an input, this is one 
of the PFIs.

Output

As an output, this is the CONVERT* 
signal. A high-to-low edge on 
CONVERT* indicates the start of an 
A/D conversion.

Table 1.  

TB-2705 Terminal Block E Series Signal Descriptions (Continued)

Signal Name

Reference

Direction

Description

Summary of Contents for PXI TB-2705

Page 1: ...terminal block assembly connects directly to the front panel of National Instruments E Series and waveform generation devices eliminating the need for an external cable The TB 2705 allows you to easil...

Page 2: ...aution which advises you of precautions to take to avoid injury data loss or a system crash italic Italic text denotes variables emphasis a cross reference or an introduction to a key concept This fon...

Page 3: ...the terminal block National Instruments is not liable for any damages or injuries resulting from incorrect signal connections Clean the module and accessories by brushing off light dust with a soft no...

Page 4: ...he analog output voltages are referenced to these terminals All three ground references AIGND AOGND and DGND are connected together on your E Series device DGND Digital Ground These pins supply the re...

Page 5: ...s is the TRIG1 signal In posttrigger data acquisition sequences a low to high transition indicates the initiation of the acquisition sequence In pretrigger applications a low to high transition indica...

Page 6: ...date As an input this is one of the PFIs Output As an output this is the UPDATE signal A high to low edge on UPDATE indicates that the analog output primary group is updating PFI6 WFTRIG DGND Input PF...

Page 7: ...UT DGND Output Frequency Output This output is from the frequency generator output Table 2 TB 2705 Terminal Block Waveform Generation Signal Descriptions Signal Name Reference Direction Description AO...

Page 8: ...s You cannot use PFI1 as an output PFI2 DGND Input PFI2 As an input this is one of the PFIs You cannot use PFI2 as an output PFI3 GPCTR1_SOURCE DGND Input PFI3 Counter 1 Source As an input this is one...

Page 9: ...e PFIs You cannot use PFI7 as an output PFI8 GPCTR0_SOURCE DGND Input PFI8 Counter 0 Source As an input this is one of the PFIs Output As an output this is the GPCTR0_SOURCE signal This signal reflect...

Page 10: ...connect your signals Refer to Figure 1 as you perform the following steps to connect signals to your terminal block Figure 1 TB 2705 Parts Locator Diagram 1 Cover 2 Cover Screws Captive 3 Strain Reli...

Page 11: ...3 22 54 8 46 50 42 18 5 37 2 1 28 61 59 62 25 58 27 21 20 55 16 48 35 11 43 41 6 4 ACH0 ACH8 AIGND ACH1 ACH9 AIGND ACH2 ACH10 AIGND ACH7 ACH15 DAC0OUT AOGND 5V SCANCLK DGND PFI3 GPCTR1_SOURCE DGND PFI...

Page 12: ...UT AOGND AOGND AOGND DIO4 DIO0 DIO1 DGND DGND DIO5 DIO2 DIO3 EXTSTROBE PFI1 5V GPCTR1_OUT PFI7 PFI9 DGND P I N S I G N A L P I N S I G N A L P I N S I G N A L 6 8 3 4 2 9 3 3 6 6 2 4 6 5 3 1 5 6 5 7 2...

Page 13: ...hten or replace the strain relief screws 8 Replace the terminal block cover and tighten the cover screws Installing the Terminal Block Refer to Figure 5 as you perform the following steps to connect t...

Page 14: ...der that reduces the voltage to within the input range of the DAQ device Input voltages greater than 42 V can damage the TB 2705 any device connected to it and the host computer Overvoltage can also c...

Page 15: ...ge temperature 20 to 70 C Relative humidity 10 to 90 noncondensing Safety Designed in accordance with IEC61010 01 EN 61010 1 UL 3111 1 and CAN CSA C22 2 No 1010 1 for electrical measuring and testing...

Page 16: ...nical support resources on our Web site and still cannot find the answers you need contact your local office or National Instruments corporate For telephone support in the United States dial 512 795 8...