Getting Started with NI 7340/7350 Controllers and AKD Drives
|
© National Instruments
|
17
Figure 10 shows the X1 connector pin assignment and wire colors.
Figure 10.
UMI-7772/74 to AKD Ca
b
le X1 Connector
Using a UMI-7764
The +24 V power supply provides the logic power to the AKD servo drive.
Complete the following steps to connect the +24 V power supply to the UMI-7764 to AKD
cable. Figure 6 shows the UMI-7764 to AKD Drive Cable +24V power supply leads.
Note
Do not plug in or turn on the +24 V power supply until after you complete
Step 7: Connect the Drive Communication
Configuration and Installation
1.
Connect the +24 V power supply (+) terminal to the wire l24V on the UMI-7764
to AKD cable.
2.
Connect the +24 V power supply return (–) terminal to the wire labeled GND on the
UMI-7764 to AKD cable.
X1
3
-Pin
Connector
+24 V
GND (Bl
a
ck)
S
TO
Summary of Contents for PXI-7358