background image

© 2006–2015 National Instruments. All rights reserved. 

371701J-01

Jun15

Refer to the 

NI Trademarks and Logo Guidelines 

at 

ni.com/trademarks

 for more information on National Instruments trademarks. Other 

product and company names mentioned herein are trademarks or trade names of their respective companies. For patents covering National 
Instruments products/technology, refer to the appropriate location: 

Help»Patents

 in your software, the 

patents.txt

 file on your media, or the 

National Instruments Patents Notice

 at 

ni.com/patents

. You can find information about end-user license agreements (EULAs) and third-party 

legal notices in the readme file for your NI product. Refer to the 

Export Compliance Information 

at 

ni.com/legal/export-compliance

 

for the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES 
NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR 
ANY ERRORS. U.S. Government Customers: The data contained in this manual was developed at private expense and is subject to the applicable 
limited rights and restricted data rights as set forth in FAR 52.227-14s, DFAR 252.227-7014, and DFAR 252.227-7015.

post-adjustment. After re-verification, update the verification date and temperature by opening 
a calibration session, and then closing the calibration session with 

action

 set to 

Commit

. If the 

NI 4110 successfully passes all verification tests, calibration is complete.

Where to Go for Support

The National Instruments website is your complete resource for technical support. At 

ni.com/

support

 you have access to everything from troubleshooting and application development 

self-help resources to email and phone assistance from NI Application Engineers.

Visit 

ni.com/services

 for NI Factory Installation Services, repairs, extended warranty, and 

other services.

Visit 

ni.com/register

 to register your National Instruments product. Product registration 

facilitates technical support and ensures that you receive important information updates from NI. 

A Declaration of Conformity (DoC) is our claim of compliance with the Council of the European 
Communities using the manufacturer’s declaration of conformity. This system affords the user 
protection for electromagnetic compatibility (EMC) and product safety. You can obtain the DoC 
for your product by visiting

 

ni.com/certification

. If your product supports calibration, 

you can obtain the calibration certificate for your product at

 

ni.com/calibration

.

National Instruments corporate headquarters is located at 11500 North Mopac Expressway, 
Austin, Texas, 78759-3504. National Instruments also has offices located around the world. For 
telephone support in the United States, create your service request at 

ni.com/support

 or dial 

1 866 ASK MYNI (275 6964). For telephone support outside the United States, visit the 
Worldwide Offices section of 

ni.com/niglobal

 to access the branch office websites, which 

provide up-to-date contact information, support phone numbers, email addresses, and current 
events.

Summary of Contents for PXI-4110

Page 1: ...st Equipment 4 Test Conditions 4 Calibration Procedures 5 Initial Setup 5 Verification 6 Verifying Voltage Programming Accuracy 7 Verifying Voltage Measurement Accuracy 8 Verifying Current Programming...

Page 2: ...Calibration File Locations NI DCPower 1 0 or Later File Name and Location Description IVI Bin nidcpower_32 dll NI DCPower driver containing the entire NI DCPower API including calibration functions I...

Page 3: ...You can shorten this calibration interval based on the accuracy demands of your application Refer to the Where to Go for Support section for more information NI PXI 4110 Getting Started Guide Contains...

Page 4: ...ween 10 and 90 noncondensing Maintain an ambient temperature of 23 C 10 C for verification procedures and an ambient temperature of 23 C 1 C for adjustment procedures Allow a warm up time of at least...

Page 5: ...date on the EEPROM to allow traceability 4 Reverification Repeat the verification procedure to ensure that the device is operating within its specifications after adjustment These steps are described...

Page 6: ...e following NI 4110 specifications Voltage programming accuracy Voltage measurement accuracy Current programming accuracy Current measurement accuracy Voltage load regulation Current load regulation V...

Page 7: ...cation Take voltage measurements using the DMM at each voltage test point and compare the reading with the value from the Output column of Table 5 Verify that the measurement error falls between the t...

Page 8: ...Take voltage measurements using the DMM at each test point and then take voltage measurements using the NI 4110 at each test point Compare the two values Verify that the measurement error falls betwee...

Page 9: ...6 are derived from the voltage measurement accuracy specifications plus an offset voltage Table 6 NI 4110 Output Parameters and Test Limits for Voltage Measurement Accuracy Verification Channel Itera...

Page 10: ...nel x in Table 4 Table 7 lists the voltage test points and external load settings that you must measure in DC Voltage mode for each current range to complete verification For example the 1 A range req...

Page 11: ...ication Channel s Output V Current Range Iteration Equivalent Resistance Output A Test Limit A 0 6 1 A 1 150 0 020000 0 004030 2 12 0 250000 0 004375 3 6 0 500000 0 004750 4 4 0 750000 0 006063 5 3 1...

Page 12: ...liary power supply for this verification procedure Refer to the following figure for the necessary connections Figure 3 Current Measurement Connection Diagram 2 16 20 mA 1 25 000 0 000400 0 000060 2 2...

Page 13: ...to settle wait three seconds after requesting a new current before taking a measurement with the DMM and the NI 4110 Verify that the measurement error falls between the absolute limits listed in the T...

Page 14: ...gulation Verification steps Connect the NI APS 4100 to the Aux Power Input connections for load regulation tests 1 2 20 mA 1 open 0 0 000012 0 000035 2 1 000 5 0 000020 0 000043 3 1 000 10 0 000027 0...

Page 15: ...e R1 to the specified channel of the NI 4110 2 While taking a current measurement with the NI 4110 I1 use the DMM to measure the voltage across the output of the NI 4110 V1 3 Change the load from R1 t...

Page 16: ...I 4110 Voltage Load Regulation Verification Points Channel VRange I Range ILimit V Level Load R1 Load R2 Measured Voltage Change Limit V Voltage Change V I1 mA V1 V I2 mA V2 V 0 6 V 1 A 1 A 6 V 620 7...

Page 17: ...oltage measurement with the NI 4110 V1 use the DMM in series to measure the output current I1 3 Change the load from R1 to R2 and repeat the previous step 4 For each test the units for all current mea...

Page 18: ...fication Points Channel VRange I Range VLimit I Level Load R1 Load R2 Measured Current Change Limit A Current Change A I1 A V1 V I2 A V2 V 0 6 V 1 A 6 V 500 mA 10 4 1 20 V 20 mA 20 V 10 mA 1 8 k 200 1...

Page 19: ...line regulation because the output voltage is fixed Run this test only after the Verifying Voltage Measurement Accuracy and Verifying Current Measurement Accuracy tests pass Voltage Line Regulation To...

Page 20: ...V1 4 Change the external variable power supply voltage from Vext1 to Vext2 and repeat the previous step 5 Record the NI 4110 output voltage measurements for both external voltages 6 Calculate the Volt...

Page 21: ...ents 21 Table 14 NI 4110 Voltage Line Regulation Verification Points Channel V Range I Range I Limit V Level Vext1 Vext2 Measured Voltage Change Limit V Voltage Change V V1 V V2 V 1 20 V 1 A 100 mA 10...

Page 22: ...the NI 4110 to output the current specified in Table 15 3 Use the DMM to measure the current across the output of the specified channel of the NI 4110 I1 4 Change the external variable power supply vo...

Page 23: ...ed specifications and adjustment is optional Table 16 NI 4110 Current Line Regulation Verification Points Channel V Range I Range V Limit I Level Vext1 Vext2 Measured Current Change Limit A Current Ch...

Page 24: ...components of the NI DCPower API require that you program the NI 4110 using the voltage output and current output functions You must adjust each range with a separate call to the appropriate niDCPower...

Page 25: ...lar output or measurement mode refer to the example programs installed with NI DCPower 3 Call niDCPower Cal Adjust function s When the measurements required for adjustment of a range are complete call...

Page 26: ...had adequate time to settle wait one second after requesting a new voltage before taking a measurement with the DMM Use the niDCPower Cal Adjust Voltage Level VI niDCPower_CalAdjustVoltageLevel functi...

Page 27: ...To ensure the system has had adequate time to settle wait one second after requesting a new voltage before taking a measurement with the DMM and the NI 4110 Use the niDCPower Cal Adjust Voltage Measu...

Page 28: ...second after requesting a new voltage before taking a measurement with the DMM Use the niDCPower Cal Adjust Current Limit VI niDCPower_CalAdjustCurrentLimit function to calculate the new calibration...

Page 29: ...ts Pass the current values reported by the NI 4110 to the Reported Outputs input of the VI and pass the voltage values measured by the DMM to the Measured Outputs input of the VI Call this VI or funct...

Page 30: ...e NI 4110 successfully passes all verification tests calibration is complete Where to Go for Support The National Instruments website is your complete resource for technical support At ni com support...