Figure 6. Synchronization Connectors on the PCIe-5785
1
1
2
1. Compact synchronization interface cable connector
2. Compact synchronization interface cable to RTSI adapter
Sharing Signals and Triggers with Another PCI
Express FlexRIO Device
1.
Install the PCIe-5785 and another PCI Express FlexRIO device in one PCI Express
backplane.
2.
Insert one end of the compact synchronization interface cable into the synchronization
connector on each PCI Express FlexRIO device. Ensure the contacts on the cable are
facing the FlexRIO device.
Sharing Signals and Triggers with PCI Express
Devices Using RTSI
1.
Mount the RTSI adapter on the top of the PCIe-5785 using the attached mounting screws.
2.
Install the PCIe-5785 and up to five additional PCI Express devices in one PCI Express
backplane.
PCIe-5785 Getting Started Guide
|
© National Instruments
|
13