occur in electrical distribution systems. The following is a description of 
Measurement (Installation

1

) Categories:

Measurement Category I is for measurements performed on circuits 
not directly connected to the electrical distribution system referred to 
as MAINS

2

 voltage. This category is for measurements of voltages 

from specially protected secondary circuits. Such voltage 
measurements include signal levels, special equipment, limited-energy 
parts of equipment, circuits powered by regulated low-voltage sources, 
and electronics.

Measurement Category II is for measurements performed on circuits 
directly connected to the electrical distribution system. This category 
refers to local-level electrical distribution, such as that provided by a 
standard wall outlet (e.g., 115 V for U.S. or 230 V for Europe). 
Examples of Measurement Category II are measurements performed 
on household appliances, portable tools, and similar products.

Measurement Category III is for measurements performed in the 
building installation at the distribution level. This category refers to 
measurements on hard-wired equipment such as equipment in fixed 
installations, distribution boards, and circuit breakers. Other examples 
are wiring, including cables, bus-bars, junction boxes, switches, 
socket-outlets in the fixed installation, and stationary motors with 
permanent connections to fixed installations.

Measurement Category IV is for measurements performed at the 
primary electrical supply installation (<1,000 V). Examples include 
electricity meters and measurements on primary overcurrent 
protection devices and on ripple control units.

Unpacking

The NI 8254R ships in an antistatic package to prevent electrostatic 
discharge from damaging device components. To avoid such damage in 
handling the device, take the following precautions:

Ground yourself using a grounding strap or by holding a grounded 
object, such as the computer chassis.

Touch the antistatic package to a metal part of the computer chassis 
before removing the device from the package.

Caution

Never touch the exposed pins of connectors.

1   

Measurement Category is also referred to as Installation Category.

2   

MAINS is defined as the (hazardous live) electrical supply system to which equipment is designed to be connected for the 
purpose of powering the equipment. Suitably rated measuring circuits may be connected to the MAINS for measuring 
purposes.

Summary of Contents for NI VISION PCI-8254R

Page 1: ...I Vision Acquisition Software 8 0 or later NI Vision Acquisition Software Release Notes Computer running Windows 2000 XP with at least one PCI slot IEEE 1394 camera IEEE 1394a cable Cable for digital...

Page 2: ...formation Caution The following paragraphs contain important safety information you must follow when installing and operating the device Do not operate the device in a manner not specified in the docu...

Page 3: ...ecomes conductive because of condensation Pollution Degree 3 Conductive pollution or dry nonconductive pollution occurs Nonconductive pollution becomes conductive because of condensation Clean the dev...

Page 4: ...ts on hard wired equipment such as equipment in fixed installations distribution boards and circuit breakers Other examples are wiring including cables bus bars junction boxes switches socket outlets...

Page 5: ...To protect yourself and the computer from electrical hazards the computer must remain unplugged until the installation is complete 3 Remove the computer cover to expose the expansion slots 4 Choose an...

Page 6: ...puter The NI 8254R is now installed and your camera is connected Refer to Figure 1 for information about placement of the connectors on the NI 8254R Figure 1 NI 8254R Connectors Wiring Isolated Output...

Page 7: ...tor to the V position on the 2 position isolated outputs power connector shown in Figure 3 b Reconnect the wire that was connected to the C position on the 4 position power connector to the C position...

Page 8: ...e around the ferrite two times as shown in Figures 4 and 5 Figure 4 Installing a Ferrite Connector on the Power Supply Cable Figure 5 Closed Ferrite on the Power Supply Cable 4 Plug the power supply c...

Page 9: ...supply you can optionally use 0 75 mm2 18 AWG ferrules according to the manufacturer specifications to terminate the wires leading to the 2 position power connector shown in Figure 7 Ferrules are avai...

Page 10: ...nize the device and assign resources to it Use Measurement Automation Explorer MAX the National Instruments configuration utility to configure the IEEE 1394 camera connected to the NI 8254R for acquis...

Page 11: ...hannels 10 Output voltage range 0 V to 5 V 1 The bus power specification assumes that power is provided to the NI 8254R device from the host computer power supply via the ATX power connector If power...

Page 12: ...lse rate 100 kHz Minimum pulse detected 10 s Reverse polarity protection Yes 30 V Isolated Current Sourcing Outputs Number of channels 4 On state voltage range 5 V to 30 V maximum Maximum on state vol...

Page 13: ...not use the NI 8254R for connection to signals within Measurement Categories II III or IV Measurement Category I Approved at altitudes up to 2 000 m Safety The NI 8254R is designed to meet the require...

Page 14: ...73 23 EEC Low Voltage Directive safety 89 336 EEC Electromagnetic Compatibility Directive EMC Note Refer to the Declaration of Conformity DoC for this product for any additional regulatory compliance...

Page 15: ...has offices located around the world to help address your support needs For telephone support in the United States create your service request at ni com support and follow the calling instructions or...

Page 16: ...l Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products refer to the ap...

Reviews: