background image

NI USB-9264 User Guide and Specifications

6

ni.com

Device Documentation and Specifications

Check 

ni.com/manuals

 for the most recent device and software 

documentation. If you do not have Web access, NI-DAQmx includes a 
Documentation CD that includes documentation available when 
NI-DAQmx released.

Training Courses

If you need more help getting started developing an application with 
NI products, NI offers training courses. To enroll in a course or obtain 
a detailed course outline, refer to 

ni.com/training

Technical Support on the Web

For additional support, refer to 

ni.com/support

 or 

zone.ni.com

.

.NET Languages without 
NI Application Software

*

NI-DAQmx .NET 
Help

—contains conceptual 

topics for using NI-DAQmx 
with Visual C# and Visual 
Basic .NET.

Start»All Programs»
National Instruments»
NI-DAQ»NI-DAQmx .NET 
Reference Help

. Expand 

NI Measurement Studio 
Help»NI Measurement 
Studio .NET Class Library»
Reference

 to view the function 

reference. Expand 

NI Measurement Studio 
Help»NI Measurement 
Studio .NET Class Library»
Using the Measurement 
Studio .NET Class Libraries

 

Visual Studio .NET 
Help

—contains conceptual 

topics for using NI-DAQmx 
with Visual C# and Visual 
Basic .NET.

Help»Contents

. Select 

Measurement Studio

 from 

the 

Filtered By

 drop-down list 

and follow the location 
instructions for the 

NI-DAQmx 

.NET Help

.

With the Microsoft .NET Framework version 1.1 or later, you can use NI-DAQmx to create applications using Visual C# 

and Visual Basic .NET without Measurement Studio. You need Microsoft Visual Studio .NET 2003 or Microsoft Visual 
Studio 2005 for the API documentation to be installed.

Table 1.  

Related Documentation (Continued)

Software

Document/Description 

Location/Topic

Summary of Contents for NI USB-9264

Page 1: ...nstruments USB 9264 and lists the device specifications Introduction The NI USB 9264 consists of two components an NI 9264 module and an NI USB 9162 carrier as shown in Figure 1 Figure 1 NI USB 9264 C...

Page 2: ...es A hazardous voltage is a voltage greater than 42 4 Vpk or 60 VDC to earth ground If hazardous voltages are connected to the module take the following precautions Caution Ensure that hazardous volta...

Page 3: ...terminals are not accessible Figure 3 NI 9940 Connector Backshell Related Documentation Each application software package and driver includes information about writing applications for taking measurem...

Page 4: ...general information about measurement concepts key NI DAQmx concepts and common applications that are applicable to all programming environments Start All Programs National Instruments NI DAQ NI DAQmx...

Page 5: ...ains NI DAQmx measurement concepts and step by step instructions about creating a measurement task using the DAQ Assistant Help Contents then select Using LabWindows CVI Data Acquisition Taking an NI...

Page 6: ...Basic NET Start All Programs National Instruments NI DAQ NI DAQmx NET Reference Help Expand NI Measurement Studio Help NI Measurement Studio NET Class Library Reference to view the function reference...

Page 7: ...structions that accompany your software Example Programs The NI DAQmx media contains example programs that you can use to get started programming with the NI USB 9264 Refer to the NI DAQmx for USB Dev...

Page 8: ...r are packaged separately Refer to Figure 5 while completing the following assembly steps 1 Make sure that no signals are connected to the NI 9264 module and the USB cable is not attached to the USB 9...

Page 9: ...onnected to a USB port the LED blinks steadily to indicate that the device is initialized and is receiving power from the connection If the LED is not blinking it may mean that the device is not initi...

Page 10: ...there are four additional COM terminals at the bottom of the connector All of the COM terminals are internally connected to the isolated ground reference of the module When connecting a load to the N...

Page 11: ...more information about startup voltage Refer to the software help for information about configuring startup output states in software Connecting Wires to the NI USB 9264 Connector Use a flathead screw...

Page 12: ...herwise noted All voltages are relative to COM unless otherwise noted Output Characteristics Number of channels 16 analog output channels DAC resolution 16 bits Type of DAC String Output range Minimum...

Page 13: ...o 1 LSB 20 V step 20 s 1 V step 15 s 0 1 V step 13 s Capacitive drive 1 500 pF max Monotonicity 16 bits DNL 1 LSB max INL endpoint 12 LSBs max Power Requirements Current consumption from USB 1 W max S...

Page 14: ...n circuits directly connected to the electrical distribution system This category refers to local level electrical distribution such as that provided by a standard wall outlet for example 115 V for U...

Page 15: ...This product meets the requirements of the following EMC standards for electrical equipment for measurement control and laboratory use EN 61326 IEC 61326 Class A emissions Basic immunity EN 55011 CIS...

Page 16: ...onal environmental information refer to the NI and the Environment Web page at ni com environment This page contains the environmental regulations and directives with which NI complies as well as othe...

Page 17: ...ustin Texas 78759 3504 National Instruments also has offices located around the world to help address your support needs For telephone support in the United States create your service request at ni co...

Reviews: