2. Right-click your network interface card (NIC) and select 

Properties

.

a.

(Windows 8.1/8/7/Vista)

 Scroll down and select 

(TCP/IPv4)

, then click 

Properties

.

b.

(Windows XP)

 Scroll down and select 

Internet Properties (TCP/IP)

, then click 

Properties

.

3. If the 

Obtain an IP address automatically

 option is selected, your PC is getting an IP 

address and a subnet mask from the DHCP server. Cancel this dialog and proceed to the 

Using DHCP

 section. 

4. If the option 

Use the following IP address 

is selected, change the subnet mask to 

255.255.0.0

 and click 

OK

.

Using DHCP

If you want to use your device on a network where all or most of the devices use dynamic IP 

addresses supplied by a DHCP server, set the rotary switch to “F”. When the device is connected 

to the network and powered on, it will obtain an IP address and a subnet mask from the server 

that is compatible with your PC. However, you will not know what address the server assigns to 

the device. The NI Stepper Configuration Utility can find your device using the 

Drive Discovery 

feature, as long as your network isn’t too large. When the device connected to the network is 

powered on, select 

Drive Discovery 

from the 

Drive

 menu to launch the 

Network Interface 

Dialog

 dialog box.

Figure 8.  

Network Interface Dialog Box

Normally, Drive Discovery only detects one network interface card (NIC), and selects it 

automatically. If you are using a laptop and have both wireless and wired network connections, 

a second NIC may appear. Please select the NIC that you use to connect to the network to which 

you’ve connected your device. Then click 

OK

. Drive Discovery notifies you as soon as it has 

detected a device. 

If you think this is the correct device, click 

Yes

. If you are not sure, click 

Not Sure

 and Drive 

Discovery will look for additional devices on you network. Once you have told Drive Discovery 

which device is yours, it automatically enters the device IP address in the IP address text box so 

that you are ready to communicate.

Summary of Contents for NI SMD-7613

Page 1: ...and Configuration 3 Step 1 Connect the Drive to the NI PS 12 13 Power Supply 3 Step 2 Connect the SMD to the Motor 4 Step 3 Connect the Drive to the Network 7 Step 4 Verify the Connections 11 Using th...

Page 2: ...Motion Module in LabVIEW To access this help file from LabVIEW select Help LabVIEW Help then expand the LabVIEW NI SoftMotion Module book on the Contents tab LabVIEW Help Use the LabVIEW Help to acces...

Page 3: ...e end of the V wire to the corresponding terminal on the included power connector Tighten the screw to ensure a secure connection 4 Connect one end of a 1 02 mm to 0 81 mm diameter 18 to 20 AWG gauge...

Page 4: ...leads present Refer to the following figures to connect your stepper motor Note Motor wire colors are correct for NI stepper motors compatible with the NI SMD 761x These wire colors may not match a th...

Page 5: ...n be connected in series or center tap Figure 3 Six Lead Motor Connected in Series Figure 4 Six Lead Motor Connected in Center Tap Phase A Green White No Connect No Connect Phase A Grn Wht Phase B Red...

Page 6: ...be connected in series or parallel Figure 5 Eight Lead Motor Connected in Series Figure 6 Eight Lead Motor Connected in Parallel Phase B Phase A Phase A Phase B Orange Org Wht Blk Wht Black Red Red W...

Page 7: ...he factory default address for each switch setting is shown in the table below The IP address corresponding to positions 1 through E can be changed using the NI Stepper Configuration Utility software...

Page 8: ...figuration Many networks use dynamic addressing where a DHCP server assigns addresses on demand The address you choose for your device might get assigned to something else by the DHCP server at anothe...

Page 9: ...mpatible with your PC However you will not know what address the server assigns to the device The NI Stepper Configuration Utility can find your device using the Drive Discovery feature as long as you...

Page 10: ...e s IP address to this interface card 6 Next enter the subnet mask as 255 255 255 0 7 Leave Default gateway blank This prevents your PC from looking for a router on this subnet Note Because you are co...

Page 11: ...r Configuration Utility 2 Locate the drive 3 Open the Drive menu and select Self Test 4 Click Start The motor should begin to move Click Stop to finish the test If the motor failed to move verify the...

Page 12: ...all the settings are configured run the VI and click the Start Move button The motor should turn according to the configured move Click the Stop Move button to stop the motor and the Stop VI when you...

Page 13: ...Worldwide Support and Services The National Instruments website is your complete resource for technical support At ni com support you have access to everything from troubleshooting and application dev...

Reviews: