background image

NI SCXI-1336 Installation Instructions

2

ni.com

bold

Bold text denotes items that you must select or click in the software, such 
as menu items and dialog box options. Bold text also denotes parameter 
names.

italic

Italic text denotes variables, emphasis, a cross reference, or an introduction 
to a key concept. This font also denotes text that is a placeholder for a word 
or value that you must supply.

monospace

Text in this font denotes text or characters that you should enter from the 
keyboard, sections of code, programming examples, and syntax examples. 
This font is also used for the proper names of disk drives, paths, directories, 
programs, subprograms, subroutines, device names, functions, operations, 
variables, filenames and extensions, and code excerpts.

1. Unpack the Terminal Block

To avoid damage in handling the terminal block, take the following 
precautions:

Caution

Never

 touch the exposed pins of connectors.

Ground yourself using a grounding strap or by touching a grounded 
object.

Touch the antistatic package to a metal part of your computer chassis 
before removing the terminal block

 

from the package.

Remove the terminal block

 

from the package and inspect the terminal block 

for loose components or any sign of damage. Notify NI if the terminal 
block

 

appears damaged in any way. Do 

not

 install a damaged terminal 

block

 

into your system.

Store the SCXI-1336 in the antistatic envelope when not in use.

2. Verify the Components

Make sure that you have the following items:

SCXI-1336 terminal block

SCXI chassis

SCXI-1129 switch module

1/8 in. flathead screwdriver

Numbers 1 and 2 Phillips screwdrivers

Summary of Contents for NI SCXI-1336

Page 1: ...ermine when to install the terminal block Visit ni com switches for information on other switching solutions Conventions The following conventions are used in this guide The symbol leads you through n...

Page 2: ...riables filenames and extensions and code excerpts 1 Unpack the Terminal Block To avoid damage in handling the terminal block take the following precautions Caution Never touch the exposed pins of con...

Page 3: ...e for more information on measurement categories When hazardous voltages 42 4 Vpk 60 VDC are present on any relay terminal safety low voltage 42 4 Vpk 60 VDC cannot be connected to any other relay ter...

Page 4: ...NI SCXI 1336 Installation Instructions 4 ni com Figure 1 SCXI 1336 Top Cover Diagram 1 Top Cover 2 Top Cover Screw 1 2...

Page 5: ...I 1336 Installation Instructions Figure 2 SCXI 1336 Parts Locator Diagram 1 Column Connectors 2 Screw Terminals 3 Rear Connector 4 Thumbscrew 5 Strain Relief Screw 6 Strain Relief Bar 7 Safety Ground...

Page 6: ...the SCXI 1129 if you have not already done so Refer to the NI Switches Getting Started Guide for more information 1 Plug the SCXI 1336 onto the front connector of the SCXI 1129 2 Tighten the top and...

Page 7: ...ect two or more SCXI 1336 terminal blocks however do not connect the SCXI 1336 with any other type of terminal block Figure 4 shows how to use a matrix expansion plug with SCXI terminal blocks to expa...

Page 8: ...2 ADC 2 AAC Environmental Operating temperature 0 to 50 C Storage temperature 20 to 70 C Humidity 10 to 90 RH noncondensing Pollution Degree 2 Approved at altitudes up to 2 000 m Indoor use only Safet...

Page 9: ...elded cabling CE Compliance This product meets the essential requirements of applicable European Directives as amended for CE marking as follows Low Voltage Directive safety 73 23 EEC Electromagnetic...

Page 10: ...al Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products refer to the a...