NI Real-Time Hypervisor 2.10 Quick Start Guide

4

ni.com

g.

Press the <W> key and then the <Enter> key to save these changes.

Note

Linux displays an error that says it failed to re-read the partition table but will 

use the new table when you reboot the system. This error is expected and does not 
indicate a problem.

10. Restart the system.

11. Use the 

mkdosfs

 utility that comes with Red Hat Enterprise Linux to name the NI ETS 

partition 

LABVIEW_RT

.

a.

Right-click the desktop and select 

Open Terminal

 from the shortcut menu.

b.

Type 

mkdosfs -n LABVIEW_RT

 followed by the name of the hard drive and the 

partition number of the NI ETS partition and then press the <Enter> key. For example, 
if the NI ETS partition is the third partition of a hard drive named /dev/sda, type 

mkdosfs -n LABVIEW_RT /dev/sda3

.

12. Upgrade your system to use GRUB2, if necessary. To determine what version of GRUB is 

running on your system, enter the command 

grub-install --version

. If the version 

is 1.98 or later, your system is running GRUB2.

Caution

If you do not follow the correct installation procedures, upgrading to 

GRUB2 can damage your system. Contact National Instruments if you require 
assistance with this process.

13. Specify the nomodeset flag to avoid screen resolution issues by completing the following 

steps:

a.

If necessary, enter the command 

mkdir /usr/local/etc/default

 to create the 

specified directory.

b.

If necessary, create the

/usr/local/etc/default/grub

 file.

c.

Open the 

/usr/local/etc/default/grub

 file for editing and add the line 

GRUB_CMDLINE_LINUX=nomodeset

 to the file.

d.

Enter the command 

grub-mkconfig -o /boot/grub/grub.cfg

 to regenerate 

grub.cfg

.

14. Install the 

kernel-rt-3.2.23-rt37.56.el6rt.x86_64

 and 

kernel-rt-devel-3.2.23-rt37.56.el6rt.x86_64

 packages.

15. Download and install the 

libXinerama (libXinerama.so.1)

 and 

mesa-libGL 

(libGL.so.1) i686

 packages using the yum package manager.

16. (Optional) If you want to use shared memory with NI Real-Time Hypervisor for Linux, you 

must install the 64-bit version of LabVIEW. National Instruments recommends you install 
LabVIEW (64-bit) before installing NI Real-Time Hypervisor to preserve default 
installation paths.

17. Place the NI Real-Time Hypervisor installation CD in the USB CD-ROM drive and run the 

NI Real-Time Hypervisor installer.

18. Right-click the desktop and select 

Open Terminal

. Then, navigate to 

/usr/local/natinst/hypervisor/ConfigurationUtility

 and run the 

Summary of Contents for NI Real-Time Hypervisor

Page 1: ...ements of the NI Real Time Hypervisor In addition FIS has partitioned this hardware between Windows and the LabVIEW Real Time OS NI ETS according to the preferences you specified during the ordering p...

Page 2: ...Expand the Devices and Interfaces tree b Right click the NI Real Time Hypervisor controller and select its controller family in the Identify As menu c Expand the tree next to the controller d Right c...

Page 3: ...our hard drive is named dev sda type fdisk dev sda b Press the N key and then the Enter key to create a new partition c Press the P key and then the Enter key to designate the partition as a primary p...

Page 4: ...ur system Contact National Instruments if you require assistance with this process 13 Specify the nomodeset flag to avoid screen resolution issues by completing the following steps a If necessary ente...

Page 5: ...to Virtualization_Drivers_Supplement txt located in the usr local natinst hypervisor directory for instructions to perform this task Pay particular attention to the supplementary text file for informa...

Page 6: ...hich each device is assigned The Advanced tab displays each device the OS to which each device is assigned and the PCI Interrupt Request Line PIRQ that each device uses 4 Optional Change the OS partit...

Page 7: ...th remote communication methods Refer to the Transferring Data Between Operating Systems topic of the NI Real Time Hypervisor Help for more information Using Shared Memory You can share up to 95 MB of...

Page 8: ...nfo and enter the Info Code NIRTHVKI to access known issues for the NI Real Time Hypervisor 2 1 Refer to ni com info and enter the Info Code HV_Devices for information about unsupported hardware devic...