background image

and by selecting 

Start

»

All Programs

»

National Instruments

»

NI FlexRIO

»

NI FlexRIO

Adapter Module Documentation

.

Related Information

Required Components

 on page 3

NI FlexRIO FPGA Module Signals

 on page 10

Installing the NI FlexRIO FPGA Module

 on page 7

Installing the NI FlexRIO Devices

Note

 

You must install the software before installing the hardware.

Unpacking

The NI 7976R modules ship in antistatic packages to prevent electrostatic discharge from
damaging module components. To prevent such damage when handling the modules, ground
yourself using a grounding strap or by holding a grounded object, such as your computer
chassis, and complete the following steps:
1. Touch the antistatic package to a metal part of the computer chassis before removing the

module from the package.

Caution

 

Never touch the exposed pins of connectors.

2. Remove each module from the package and inspect it for loose components or any other

sign of damage.

Notify NI if the modules appear damaged in any way. Do not install a damaged module into
the chassis.

Preparing the Environment

Ensure that the environment you are using the NI 7976R in meets the following specifications.

............................................................................

Operating temperature (IEC
60068-2-1, IEC60068-2-2)

0 °C to 55 °C

............................................................................

Operating humidity
(IEC 60068-2-56)

10% to 90% RH, noncondensing

............................................................................

Pollution Degree

2

............................................................................

Maximum altitude

2,000 m at 25 °C ambient temperature

Indoor use only.

Note

 

Refer to the 

NI PXIe-7976R Specifications

 at 

ni.com/manuals

 for complete

specifications.

6

  | 

ni.com

  | 

NI PXIe-7976R FPGA Module Getting Started Guide

Summary of Contents for NI PXIe-7976R

Page 1: ...PXIe 7976...

Page 2: ...ilable at Start All Programs National Instruments NI FlexRIO and at ni com manuals Contents How to Use Your NI FlexRIO Documentation Set 2 Required Components 3 Installing the Application Software and...

Page 3: ...on Getting started guide for your FPGA module Available from the Start menu and at ni com manuals Contains installation instructions for your NI FlexRIO system Specifications document for your FPGA mo...

Page 4: ...W FPGA functions and intellectual property to share NI FlexRIO product page ni com flexrio Contains product information and data sheets for NI FlexRIO devices Required Components The following items a...

Page 5: ...apter Module Support is available at ni com downloads Search for flexrio adapter module support to download the latest version of NI FlexRIO Adapter Module Support You do not need this software if you...

Page 6: ...VIEW FPGA Module Refer to the LabVIEW FPGA Module Release and Upgrade Notes for installation instructions and information about getting started with the LabVIEW FPGA Module Documentation for the LabVI...

Page 7: ...steps 1 Touch the antistatic package to a metal part of the computer chassis before removing the module from the package Caution Never touch the exposed pins of connectors 2 Remove each module from th...

Page 8: ...1062Q 1 2 3 4 5 1 PXI Express System Controller Slot 2 PXI Peripheral Slot 3 PXI Express Hybrid Peripheral Slot 4 PXI Express System Timing Slot 5 PXI Express Peripheral Slot Refer to the chassis docu...

Page 9: ...page 5 Confirming that Measurement Automation Explorer MAX Recognizes the Device Use Measurement Automation Explorer MAX to configure your National Instruments hardware MAX informs other programs abo...

Page 10: ...FlexRIO FPGA module as shown in the figure below Figure 5 Installing the NI FlexRIO Adapter Module PXI 1000B 1 4 3 2 5 1 NI FlexRIO Adapter Module 2 Captive Screw 3 Guide Pin 4 PXI PXI Express Chassi...

Page 11: ...e PXI EMC filler panel Figure 6 PXI EMC Filler Panels and Chassis 1 1 3 2 1 Captive Screw Covers 2 Captive Mounting Screws 3 EMC Gasket Note You must populate all slots with a module or a PXI EMC fill...

Page 12: ...16 GND GPIO_17_n GPIO_17 GND GPIO_18_n GPIO_18 GND GPIO_19_n GPIO_19 GND GPIO_20_n GPIO_20 GND GPIO_21_n GPIO_21 GND GPIO_22_n GPIO_22 GND GPIO_23_n GPIO_23 GND GPIO_58_n GPIO_58 GND GPIO_59_n GPIO_59...

Page 13: ...ss A emissions FCC 47 CFR Part 15B Class A emissions ICES 001 Class A emissions Note In the United States per FCC 47 CFR Class A equipment is intended for use in commercial light industrial and heavy...

Page 14: ...visit ni com environment weee RoHS National Instruments RoHS National Instruments RoHS ni com environment rohs_china For information about China RoHS compliance go to ni com environment rohs_china El...

Page 15: ...and phone assistance from NI Application Engineers Visit ni com services for NI Factory Installation Services repairs extended warranty and other services Visit ni com register to register your Nation...

Page 16: ...and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the National Instruments global trade compliance p...

Reviews: