Specifications

The following specifications apply to the NI 1428 image acquisition device. These specifications are 
typical at 25 °C unless otherwise specified.

Trigger Characteristics

Number of external trigger I/O lines......................4

Trigger input

Voltage range .................................................0 V to 5 V (TTL)

Input high voltage ..................................2.0 V

Input low voltage ...................................0.8 V

Polarity...........................................................Programmable, active high or active low

Trigger output

Voltage range .................................................0 V to 5 V (TTL)

Output high voltage................................2.4 V at 15 mA source

Output low voltage.................................0.55 V at 10 mA sink

Polarity...........................................................Programmable, active high or active low

Power-on state........................................................Input (high-impedance) 10 K

Ω

pull-up to 5 V

Pixel clock..............................................................Camera Link compatible

Enables...................................................................Camera Link compatible

Control signal.........................................................Camera Link compatible

Video data ..............................................................Camera Link compatible

Clocks

Pixel clock frequency range...................................20 MHz to 50 MHz

Note

Camera Link cameras must transmit at a minimum of 20 MHz.

1

PCI Interface

Theoretical max PCI bandwidth ............................133 MB/s

Physical Characteristics

Dimensions

NI PXI-1428 ..................................................10 cm

×

16 cm (3.9 in.

×

6.3 in.)

NI PCI-1428...................................................10.7 cm

×

17.5 cm (4.2 in.

×

6.9 in.)

Weight

NI PXI-1428 ..................................................0.172 kg (0.38 lb)

NI PCI-1428...................................................0.127 kg (0.28 lb)

1   

This value corresponds to the post-serialization Camera Link cable transmission rate of 140 MHz to 350 MHz.

Summary of Contents for NI PXI/PCI-1428

Page 1: ...ision Acquisition Software 8 2 0 or later which includes the NI IMAQ driver software Optional software for developing applications NI Vision Builder for Automated Inspection NI Vision Development Module LabVIEW LabWindows CVI Microsoft Visual Basic Optional Equipment National Instruments offers a variety of products for use with the NI 1428 including the following NI D6804 breakout cable used for ...

Page 2: ...ent is turned off To avoid a shock hazard do not perform procedures involving cover or shield removal unless you are qualified to do so Disconnect all field power prior to removing covers or shields If the device is rated for use with hazardous voltages 30 Vrms 42 4 Vpk or 60 Vdc it may require a safety earth ground connection wire Refer to the device specifications for maximum voltage ratings Bec...

Page 3: ...Measurement Category II are measurements performed on household appliances portable tools and similar products Measurement Category III is for measurements performed in the building installation at the distribution level This category refers to measurements on hard wired equipment such as equipment in fixed installations distribution boards and circuit breakers Other examples are wiring including ...

Page 4: ...ls of the PXI or CompactPCI chassis 8 Connect the MDR 26 pin Camera Link cable to the camera Refer to your camera manufacturer documentation for specific instructions about how to connect the cable to your camera 9 Connect the Camera Link cable to the Camera Link connector on the NI PXI 1428 front panel 10 Plug in and power on the PXI or CompactPCI chassis The NI PXI 1428 is now installed and the ...

Page 5: ...a_model icd supplied by National Instruments The NI IMAQ driver software uses the information in this camera file to program the NI 1428 to acquire images from a specific camera Without this camera file the driver does not have the information necessary to configure the NI 1428 to recognize the image format of the particular camera you are using Refer to MAX for information about valid camera attr...

Page 6: ...55 V at 10 mA sink Polarity Programmable active high or active low Power on state Input high impedance 10 KΩ pull up to 5 V Pixel clock Camera Link compatible Enables Camera Link compatible Control signal Camera Link compatible Video data Camera Link compatible Clocks Pixel clock frequency range 20 MHz to 50 MHz Note Camera Link cameras must transmit at a minimum of 20 MHz 1 PCI Interface Theoreti...

Page 7: ...line and click the appropriate link in the Certification column Electromagnetic Compatibility This product is designed to meet the requirements of the following standards of EMC for electrical equipment for measurement control and laboratory use EN 61326 EMC requirements Minimum Immunity EN 55011 Emissions Group 1 Class A CE C Tick ICES and FCC Part 15 Emissions Class A Note For EMC compliance ope...

Page 8: ... compatibility EMC and product safety You can obtain the DoC for your product by visiting ni com certification If your product supports calibration you can obtain the calibration certificate for your product at ni com calibration National Instruments corporate headquarters is located at 11500 North Mopac Expressway Austin Texas 78759 3504 National Instruments also has offices located around the wo...

Reviews: