Appendix A
Specifications
©
National Instruments Corporation
A-3
Operating Environment
Ambient temperature range.................... 5 to 50 °C in an NI PXI-1042
chassis (Tested in accordance
with IEC-60068-2-1 and
IEC-60068-2-2). Refer to the
datasheet linked from the
NI PXI-8104 Embedded
Controller product page
at
ni.com
for other
controller/chassis combinations.
Relative humidity range ......................... 10% to 90%, noncondensing
(Tested in accordance with
IEC-60068-2-56.)
Caution
Clean the NI PXI-8104 with a soft nonmetallic brush. Make sure that the device
is completely dry and free from contaminants before powering-on the controller again.
Storage Environment
Ambient temperature range.................... –40 to 65 °C (Tested in
accordance with IEC-60068-2-1
and IEC-60068-2-2.)
Relative humidity range ......................... 5% to 95% noncondensing
(Tested in accordance with
IEC-60068-2-56.)
Shock and Vibration
Operational shock .................................. 30 g peak, half-sine, 11 ms pulse
(Tested in accordance with
IEC-60068-2-27. Test profile
developed in accordance with
MIL-PRF-28800F.)
Random vibration
Operating ........................................ 5 to 500 Hz, 0.3 g
rms
(with solid-state hard drive)