occur in electrical distribution systems. The following is a description of 
Measurement (Installation

1

) Categories:

Measurement Category I is for measurements performed on circuits 

not

 directly connected to the electrical distribution system referred to 

as MAINS

2

 voltage. This category is for measurements of voltages 

from specially protected secondary circuits. Such voltage 
measurements include signal levels, special equipment, limited-energy 
parts of equipment, circuits powered by regulated low-voltage sources, 
and electronics.

Measurement Category II is for measurements performed on circuits 
directly connected to the electrical distribution system. This category 
refers to local-level electrical distribution, such as that provided by a 
standard wall outlet (e.g., 115 V for U.S. or 230 V for Europe). 
Examples of Measurement Category II are measurements performed 
on household appliances, portable tools, and similar products.

Measurement Category III is for measurements performed in the 
building installation at the distribution level. This category refers to 
measurements on hard-wired equipment such as equipment in fixed 
installations, distribution boards, and circuit breakers. Other examples 
are wiring, including cables, bus-bars, junction boxes, switches, 
socket-outlets in the fixed installation, and stationary motors with 
permanent connections to fixed installations.

Measurement Category IV is for measurements performed at the 
primary electrical supply installation (<1,000 V). Examples include 
electricity meters and measurements on primary overcurrent 
protection devices and on ripple control units.

Unpacking

The NI 8255R ships in an antistatic package to prevent electrostatic 
discharge from damaging device components. To avoid such damage in 
handling the device, take the following precautions:

Ground yourself via a grounding strap or by holding a grounded object, 
such as the computer chassis.

Touch the antistatic package to a metal part of the computer chassis 
before removing the device from the package.

Caution

Never

 touch the exposed pins of connectors.

1   

Measurement Category is also referred to as Installation Category.

2   

MAINS is defined as the (hazardous live) electrical supply system to which equipment is designed to be connected for the 
purpose of powering the equipment. Suitably rated measuring circuits may be connected to the MAINS for measuring 
purposes.

Summary of Contents for NI PCIe-8255

Page 1: ...are Release Notes Computer running Windows 2000 XP with at least one PCIe slot IEEE 1394 camera 9 pin IEEE 1394 cable for interfacing to IEEE 1394b cameras 6 pin to 9 pin cable or 6 pin to 9 pin adapt...

Page 2: ...afety Information Caution The following paragraphs contain important safety information you must follow when installing and operating the device Do not operate the device in a manner not specified in...

Page 3: ...mes conductive because of condensation Pollution Degree 3 Conductive pollution or dry nonconductive pollution occurs Nonconductive pollution becomes conductive because of condensation Clean the device...

Page 4: ...s on hard wired equipment such as equipment in fixed installations distribution boards and circuit breakers Other examples are wiring including cables bus bars junction boxes switches socket outlets i...

Page 5: ...are Release Notes for installation and configuration instructions 2 Power off and unplug the computer Caution To protect yourself and the computer from electrical hazards the computer must remain unpl...

Page 6: ...and gently rock the NI 8255R into the slot The connection may be tight but do not force the device into place Note Check that the bracket of the NI 8255R lines up with the hole in the back panel rail...

Page 7: ...nnector on the NI 8255R front panel Refer to Figure 2 for the location of the IEEE 1394b bilingual connectors on the NI 8255R If you are using an IEEE 1394a cable an IEEE 1394a to IEEE 1394b adapter i...

Page 8: ...ou are using a power supply other than the NI desktop power supply skip this step and proceed to step 2 a Disconnect the 4 position power connector from the power supply as shown in Figure 3 Figure 3...

Page 9: ...I Vision I O Terminal Block and Prototyping Accessory Refer to Table 1 for a summary of the isolated power supply connections 3 Optional To suppress electromagnetic interference install a ferrite on t...

Page 10: ...sign resources to it Use Measurement Automation Explorer MAX the National Instruments configuration utility to configure the IEEE 1394 camera connected to the NI 8255R for acquisition Note You must in...

Page 11: ...z Minimum pulse detected 500 ns Power on state Input high impedance 61 9 k pull up to 5V 1 The bus power specification assumes that power is provided to the NI 8255R device from the host computer powe...

Page 12: ...V Turn on current 7 1 mA typical 14 mA maximum Maximum pulse rate 100 kHz Minimum pulse detected 10 s Reverse polarity protection Yes 30 V Isolated Current Sourcing Outputs Number of channels 4 On st...

Page 13: ...x4 x8 x16 Physical Characteristics Dimensions 11 2 cm 16 8 cm 4 4 in 6 6 in Weight 130 g 4 5 oz Environment The NI 8255R device is intended for indoor use only Operating temperature 0 C to 55 C Storag...

Page 14: ...ons Class A Note For EMC compliance operate this device with shielded cabling CE Compliance The NI 8255R meets the essential requirements of applicable European Directives as amended for CE marking as...

Page 15: ...as offices located around the world to help address your support needs For telephone support in the United States create your service request at ni com support and follow the calling instructions or d...

Page 16: ...nal Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products refer to the...

Reviews: