Chapter 4
Programming with NI-IMAQ for 1394 VIs
NI-IMAQ for IEEE-1394 Cameras User Manual
4-10
ni.com
Your intensity graph now should appear similar to the image shown in
Figure 4-9. For more information on the Intensity Graph, consult your
LabVIEW documentation
Figure 4-9.
Intensity Graph for Image Display
Use the
IMAQ ImageToArray
VI to copy an image from an image buffer
into a LabVIEW array. Then you can wire this array directly to an Intensity
Graph for display. Figure 4-10 illustrates using an Intensity Graph to
display an image acquired using
IMAQ1394 Snap
.
Figure 4-10.
Displaying an Image Using an Intensity Graph
To display an RGB image on a picture control, place the picture control on
the front panel of your VI. Use the
IMAQ ColorImageToArray
VI to copy
an image from an image buffer into a LabVIEW array. Then you can wire
this array to the
Draw True-Color Pixmap
VI. Wire the new image output
from
Draw True-Color Pixmap
to the picture control indicator. For more
information on the picture control, consult the LabVIEW online reference.
Figure 4-11 illustrates using a picture control to display an RGB image
acquired with the
IMAQ1394 Snap
VI.