Configuring the Hardware
Remove the NI CVS-1458 from the package and inspect the system for damage. Notify National
Instruments if the system appears damaged in any way. Do not use a damaged system.
Ensure that the AC input to the external power supply is disconnected before plugging in or
unplugging any connector. Ground the unit to minimize the possibility of static electricity
damage.
Complete the following sections to wire power to the NI CVS-1458, connect cameras, and
connect the NI CVS-1458 to a network. Figure 1 and Figure 2 show the features on the device.
Figure 1.
NI CVS-1458 Power Connectors and Reset Button
1
Reset Button
2
System Power Connector
3
Isolated Output and PoE Power Connector
4
Chassis Grounding Screw
S
YSTEM
Po
E
48 V
IS
O
C
ISO
C
Po
E
V
Po
E
V
ISO
5-24
V
12
-24
V
C
V
2
3
1
4