Internal Real-Time Clock

The cRIO-9022 system clock synchronizes with the internal high-precision real-time clock

during startup. This synchronization provides timestamp data to the cRIO-9022. You can use

the internal real-time clock to correct drift of the system clock.

Related Information

Internal RTC

 on page 14

USB Mass-Storage Devices

The cRIO-9022 supports common USB mass-storage devices such as USB Flash drives and
USB-to-IDE adapters formatted with FAT16 and FAT32 file systems. LabVIEW maps USB
devices to the 

U:

V:

W:

, or 

X:

 drive, starting with the 

U:

 drive if it is available. You can

connect multiple USB mass-storage devices to the cRIO-9022 if you use a USB hub. Refer to
the 

LabVIEW Help

 for more information.

Note

 

If the cRIO-9022 is not in a hazardous location, you can connect and

disconnect USB devices without affecting operation.

DIP Switches

cRIO-9022 DIP switches are in the OFF position by default.

Figure 7.

 Controller DIP Switches

SAFE MODE

CONSOLE OUT

IP RESET

NO APP

USER1

OFF

ON

SAFE MODE Switch

The following table describes the ON and OFF states of the SAFE MODE switch.

NI cRIO-9022 User Manual and Specifications

  | 

© National Instruments

  | 

9

Summary of Contents for NI cRIO-9022

Page 1: ...cRIO 9022...

Page 2: ...LEDs 2 Power Connector 3 RS 232 Serial Port 4 USB Port 5 USB Retention Standoff 6 Reset Button 7 DIP Switches 8 RJ 45 Ethernet Port 1 9 RJ 45 Ethernet Port 2 Refer to the reconfigurable chassis docum...

Page 3: ...ution For Division 2 and Zone 2 applications install the system in an enclosure rated to at least IP54 as defined by IEC EN 60079 15 Special Conditions for Hazardous Locations Use in Europe and Intern...

Page 4: ...e product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules Special Conditions for Marine Applications Some products are Lloyd s...

Page 5: ...he chassis connector Press firmly to ensure the chassis connector and the cRIO 9022 connector are mated 4 Using a Phillips 2 screwdriver tighten the two captive screws on the front of the cRIO 9022 to...

Page 6: ...tandard Ethernet connection If neither the host computer nor the controller is connected to a network you can connect the two directly Caution To prevent data loss and maintain the integrity of your E...

Page 7: ...r for the C Series modules The cRIO 9022 has a primary power input V1 and a secondary power input V2 The cRIO 9022 draws power from the power supply with the higher voltage The cRIO 9022 has one layer...

Page 8: ...he Power and Status LEDs turn on When the Status LED turns off the POST is complete Related Information LEDs on page 11 Configuring IP Settings and Installing Software on the cRIO 9022 The cRIO 9022 i...

Page 9: ...ch the LabVIEW Real Time Software Wizard 11 Install LabVIEW Real Time software and device drivers on the controller The cRIO 9022 automatically reboots after the software installation You can now prog...

Page 10: ...systems LabVIEW maps USB devices to the U V W or X drive starting with the U drive if it is available You can connect multiple USB mass storage devices to the cRIO 9022 if you use a USB hub Refer to...

Page 11: ...of the CONSOLE OUT switch Table 2 CONSOLE OUT Switch States State Description ON Enables console out You can read the IP address and firmware version of the cRIO 9022 using a serial port terminal prog...

Page 12: ...application is automatically enabled Note If you want to permanently disable the application from running when the controller powers on you must disable it in LabVIEW For more information about automa...

Page 13: ...surement Automation Explorer MAX Help for information about configuring devices Blinks twice and pauses An error can occur when an attempt to upgrade the software is interrupted Reinstall software on...

Page 14: ...he cRIO 9022 to the default network settings 1 Move the IP RESET switch to the ON position 2 Push the RESET button to cycle power to the cRIO 9022 The STATUS LED flashes once indicating that the cRIO...

Page 15: ...bps auto negotiated Maximum cabling distance 100 m segment RS 232 DTE Serial Port Baud rate 300 bps to 230 400 bps Data bits 5 6 7 8 Stop bits 1 1 5 2 Parity Odd even mark space none Flow control RTS...

Page 16: ...is applied to V and C After powerup it can operate on as little as 6 V Physical Characteristics If you need to clean the controller wipe it with a dry towel Screw terminal wiring Gauge 0 33 mm 2 to 2...

Page 17: ...bles You can order the NI 9979 strain relief kit for the power cable For information about using the USB port in high shock and vibration environments contact NI Operating vibration Random IEC 60068 2...

Page 18: ...dustrial immunity EN 55011 CISPR 11 Group 1 Class A emissions AS NZS CISPR 11 Group 1 Class A emissions FCC 47 CFR Part 15B Class A emissions ICES 001 Class A emissions Note For the standards applied...

Page 19: ...lectrical and electronic equipment WEEE All products at the end of their life cycle must be sent to a WEEE collection and recycling center Proper WEEE disposal reduces environmental impact and the ris...

Page 20: ...u receive important information updates from NI A Declaration of Conformity DoC is our claim of compliance with the Council of the European Communities using the manufacturer s declaration of conformi...

Page 21: ...u can find information about end user license agreements EULAs and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export co...

Reviews: