Page 1: ...nderutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In stock Ready to ship TAR certified secure asset solutions Expert team I Trust guarantee I 100 satisfaction All trademarks brand names and brands appearing herein are the property of their respective ow...

Page 2: ...GETTING STARTED GUIDE NI 9775 4 Ch 10 V 20 MS s 14 Bit Digitizer hnology Group Quality Instrumentation Guaranteed 888 88 SOURCE www ...

Page 3: ...ch component in the system to determine the safety and EMC ratings for the entire system Safety Guidelines Operate the NI 9775 only as described in this document Caution Do not operate the NI 9775 in a manner not specified in this document Product misuse can result in a hazard You can compromise the safety protection built into the product if the product is damaged in any way If the product is dam...

Page 4: ...tions of Measurement Categories CAT II CAT III or CAT IV Caution Do not connect the NI 9775 to signals or use for measurements within Measurement Categories II III or IV Safety Guidelines for Hazardous Locations The NI 9775 is suitable for use in Class I Division 2 Groups A B C D T4 hazardous locations Class I Zone 2 AEx nA IIC T4 and Ex nA IIC T4 hazardous locations and nonhazardous NI 9775 Getti...

Page 5: ...bstitution of components may impair suitability for Class I Division 2 Caution For Division 2 and Zone 2 applications install the system in an enclosure rated to at least IP54 as defined by IEC EN 60079 15 Special Conditions for Hazardous Locations Use in Europe and Internationally The NI 9775 has been evaluated as Ex nA IIC T4 Gc equipment under DEMKO 12 ATEX 1202658X and is IECEx UL 14 0089X cer...

Page 6: ... shall be mounted in an ATEX IECEx certified enclosure with a minimum ingress protection rating of at least IP54 as defined in IEC EN 60079 15 Caution The enclosure must have a door or cover accessible only by the use of a tool Electromagnetic Compatibility Guidelines This product was tested and complies with the regulatory requirements and limits for electromagnetic compatibility EMC stated in th...

Page 7: ...nce with the instructions in the product documentation Furthermore any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory rules Caution To ensure the specified EMC performance operate this product only with shielded cables and accessories Do not use unshielded cables or accessories unless they a...

Page 8: ...tion for a product visit ni com certification and search for the LR certificate or look for the Lloyd s Register mark on the product Caution In order to meet the EMC requirements for marine applications install the product in a shielded enclosure with shielded and or filtered power and input output ports In addition take precautions when designing selecting and installing measurement probes and ca...

Page 9: ...EC 60068 2 1 IEC 60068 2 2 40 C to 70 C Operating humidity IEC 60068 2 78 10 RH to 90 RH noncondensing Pollution Degree 2 Maximum altitude 5 000 m Indoor use only Note Refer to the device datasheet on ni com manuals for complete specifications 8 ni com NI 9775 Getting Started Guide hnology Group Quality Instrumentation Guaranteed 888 88 SOURCE www ...

Page 10: ...NI 9775 Pinout AI0 CHASSIS GND AI1 CHASSIS GND AI2 CHASSIS GND AI3 CHASSIS GND NI 9775 Getting Started Guide National Instruments 9 hnology Group Quality Instrumentation Guaranteed 888 88 SOURCE www ...

Page 11: ...ription AI Analog input signal connection CHASSIS GND Chassis ground connection Single Ended Connections NI 9775 Source CHASSIS GND AI 10 ni com NI 9775 Getting Started Guide hnology Group Quality Instrumentation Guaranteed 888 88 SOURCE www ...

Page 12: ...fications Overvoltage Protection The NI 9775 provides overvoltage protection for each channel Note Refer to the device datasheet on ni com manuals for more information about overvoltage protection NI 9775 Getting Started Guide National Instruments 11 hnology Group Quality Instrumentation Guaranteed 888 88 SOURCE www ...

Page 13: ...ocumentation Resources ni com info cseriesdoc Services ni com services Installs with the software NI 9775 Datasheet NI RIO Help LabVIEW FPGA Help NI 9775 Datasheet NI DAQmx Help LabVIEW Help 12 ni com NI 9775 Getting Started Guide hnology Group Quality Instrumentation Guaranteed 888 88 SOURCE www ...

Page 14: ...ates technical support and ensures that you receive important information updates from NI A Declaration of Conformity DoC is our claim of compliance with the Council of the European Communities using the manufacturer s declaration of conformity This system affords the user protection for electromagnetic compatibility EMC and product safety You can obtain the DoC for your product by visiting ni com...

Page 15: ...propriate location Help Patents in your software the patents txt file on your media or the National Instruments Patent Notice at ni com patents You can find information about end user license agreements EULAs and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and...

Page 16: ...quipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentation Artisan Scientific Corporation dba Artisan Technology Group is not an affiliate representative or authorized distributor for any manufacturer listed herein We re here to make your life easier How...

Reviews: