![background image](http://html2.mh-extra.com/html/national-instruments/ni-9514/ni-9514_operating-instructions-and-specifications_3393023027.webp)
26
|
ni.com
|
NI 9514Operating Instructions and Specifications
Drive enable output
Output type ................................. Software-selectable:
sinking or sourcing
Voltage range.............................. 0 to 30 V
Vsup input .................................. 19 to 30 V
Continuous output current (
I
0
)
on each channel .......................... ±100 mA max
Output impedance (
R
0
) ............... 0.3
Ω
max
Output voltage (
V
0
) sourcing
......V
sup
- (
I
0
R
0
)
Output voltage (
V
0
) sinking
........I
0
R
0
Min output pulse width .............. 100
μ
s
Active state ................................. Software-selectable:
on or off
Motion I/O
Encoder 0 Phase A/B and Index inputs
Type ............................................ RS-422 differential or
single-ended inputs
Digital logic levels, single-ended
Voltage ................................. -0.25 to 5.25 V