Environmental
Refer to the manual for the chassis you are using for more
information about meeting these specifications.
Operating temperature
(IEC 60068-2-1, IEC 60068-2-2) ..... -40 to 70 °C
Storage temperature
(IEC 60068-2-1, IEC 60068-2-2) ..... -40 to 85 °C
Ingress protection.............................. IP 40
Operating humidity
(IEC 60068-2-56).............................. 10 to 90% RH,
noncondensing
Storage humidity
(IEC 60068-2-56).............................. 5 to 95% RH,
noncondensing
Pollution Degree (IEC 60664) .......... 2
Maximum altitude............................. 5,000 m
Indoor use only.