National Instruments NI 9469 Getting Started Manual Download Page 9

Figure 1.

 Routing Capabilities of the Crosspoint Switch

Line 0 

Line 1

Line 2

Line 3

Line 0 

Line 1

Line 2

Line 3

Line 0 

Line 1

Line 2

Line 3

Tr

ig 0

Tr

ig 1

Tr

ig 2

Tr

ig 3

Line 0

Line 1

Line 2

Line 3

Line 0

Line 1

Line 2

Line 3

Line 0

Line 1

Line 2

Line 3

Trig 0

Trig 1

Trig 2

Trig 3

Clk Gen

Sources

P

or

t 0

P

or

t 1

P

or

t 2

Bac

kplane

Onboard

Destinations

Port 0

Port 1

Port 2

Backplane

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

x

NI 9469 Getting Started Guide

  | 

© National Instruments

  | 

9

Summary of Contents for NI 9469

Page 1: ...GETTING STARTED GUIDE NI 9469 Synchronization Module Fran ais Deutsch ni com manuals This document explains how to connect to the NI 9469...

Page 2: ...ystem to determine the safety and EMC ratings for the entire system Safety Guidelines Operate the NI 9469 only as described in this document Hot Surface This icon denotes that the component may be hot...

Page 3: ...onment Not following these guidelines may result in serious injury or death Caution Do not disconnect I O side wires or connectors unless power has been switched off or the area is known to be nonhaza...

Page 4: ...Gas Group IIC hazardous locations you must use the device in an NI chassis that has been evaluated as Ex nC IIC T4 Ex IIC T4 Ex nA IIC T4 or Ex nL IIC T4 equipment Caution You must make sure that tran...

Page 5: ...intended for use in industrial locations However harmful interference may occur in some installations when the product is connected to a peripheral device or test object or if the product is used in r...

Page 6: ...product visit ni com certification and search for the LR certificate or look for the Lloyd s Register mark on the product Caution In order to meet the EMC requirements for marine applications install...

Page 7: ...469 has three RJ45 connectors on the front panel labeled Port 0 1 and 2 These connectors use standard straight through CAT 5e Ethernet cabling to provide connection to other NI 9469 modules only Each...

Page 8: ...e crosspoint switch is not a full routing matrix You can connect only the same Line or Trig number For example Line 0 to Trig 0 but not Line 0 to Trig 2 However you can route clock signals on only Lin...

Page 9: ...Line 0 Line 1 Line 2 Line 3 Line 0 Line 1 Line 2 Line 3 Line 0 Line 1 Line 2 Line 3 Trig 0 Trig 1 Trig 2 Trig 3 Clk Gen Sources Port 0 Port 1 Port 2 Backplane Onboard Destinations Port 0 Port 1 Port 2...

Page 10: ...nected with a tree topology Figure 2 shows a tree topology example More advanced and customizable options create a flexible topological network of NI 9469 modules Refer to the Topologies section for e...

Page 11: ...example If maximum separation distance is required connect the modules using a daisy chain topology with maximum cable length per hop as shown in Figure 4 Refer to the Cable section for information a...

Page 12: ...y Out In Out Out In Out Out In Out Out In Out Out Out In Out In Out In Out Out Master Chassis 1 Slave Chassis 5 Slave Chassis 2 Slave Chassis 6 Slave Chassis 7 Slave Chassis 4 Slave Chassis 3 12 ni co...

Page 13: ...ut In Out Out In In Out Out In Out Out In Out Out Out Out In In Out Out Slave Master Slave Chassis 1 Slave Chassis 3 Slave Chassis 4 Slave Chassis 6 Slave Chassis 5 Slave Chassis 7 Slave Chassis 2 NI...

Page 14: ...ain Topology In Out Out In Out Out In Out Out In Out Out In Out Out In Out Out Master Chassis 1 Slave Chassis 2 Slave Chassis 3 Slave Chassis 4 Slave Chassis 5 Slave Chassis 6 14 ni com NI 9469 Gettin...

Page 15: ...t In Out Out Out Out In In Out Out In Out Out In Out Out In Out Out Master Slave Chassis 1 Slave Slave Chassis 5 Slave Chassis 2 Slave Chassis 3 Slave Chassis 4 Slave Chassis 7 Slave Chassis 8 Slave C...

Page 16: ...for information about support for sleep mode If the chassis supports sleep mode refer to the software help for information about enabling sleep mode Visit ni com info and enter cseriesdoc for informat...

Page 17: ...ons The following specifications are typical for the range 40 C to 70 C unless otherwise noted I O Characteristics Front panel connectors Shielded RJ45 receptacle Front panel indicators 4 green LEDs N...

Page 18: ...12 8 MHz or 13 1072 MHz Accuracy 3 5 ppm typical Cable Type1 CAT 5e Shielded Twisted Pair straight through Maximum propagation delay2 4 98 ns m Maximum length 100 m 1 Refer to the I O Characteristics...

Page 19: ...Thermal dissipation at 70 C Active mode 1 W max Sleep mode 25 W Physical Characteristics To clean the module wipe it with a dry towel Weight 148 g 5 2 oz Safety Voltages Isolation Channel to channel N...

Page 20: ...ontrol and laboratory use IEC 61010 1 EN 61010 1 UL 61010 1 CSA 61010 1 EN 60079 0 2012 EN 60079 15 2010 IEC 60079 0 Ed 6 IEC 60079 15 Ed 4 UL 60079 0 Ed 5 UL 60079 15 Ed 3 CSA 60079 0 2011 CSA 60079...

Page 21: ...Compatibility This product meets the requirements of the following EMC standards for electrical equipment for measurement control and laboratory use EN 61326 1 IEC 61326 1 Class A emissions Industrial...

Page 22: ...tended for use only in heavy industrial locations Note Group 1 equipment per CISPR 11 is any industrial scientific or medical equipment that does not intentionally generate radio frequency energy for...

Page 23: ...Potentially Explosive Atmospheres ATEX Online Product Certification Refer to the product Declaration of Conformity DoC for additional regulatory compliance information To obtain product certifications...

Page 24: ...Hz Operating shock IEC 60068 2 27 30 g 11 ms half sine 50 g 3 ms half sine 18 shocks at 6 orientations Environmental Refer to the manual for the chassis you are using for more information about meeti...

Page 25: ...vironmentally responsible manner NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers For additional environmental informa...

Page 26: ...sit ni com environment weee RoHS National Instruments RoHS National Instruments RoHS ni com environment rohs_china For information about China RoHS compliance go to ni com environment rohs_china World...

Page 27: ...of conformity This system affords the user protection for electromagnetic compatibility EMC and product safety You can obtain the DoC for your product by visiting ni com certification If your product...

Page 28: ...Notice at ni com patents You can find information about end user license agreements EULAs and third party legal notices in the readme file for your NI product Refer to the Export Compliance Informatio...

Reviews: