Measurement Category I

Caution

 Do not connect the product to signals or use for measurements

within Measurement Categories II, III, or IV.

Attention

 Ne pas connecter le produit à des signaux dans les catégories

de mesure II, III ou IV et ne pas l'utiliser pour effectuer des mesures dans

ces catégories.

Warning

 Do not connect the product to signals or use for measurements

within Measurement Categories II, III, or IV, or for measurements on MAINs

circuits or on circuits derived from Overvoltage Category II, III, or IV which

may have transient overvoltages above what the product can withstand.

The product must not be connected to circuits that have a maximum

voltage above the continuous working voltage, relative to earth or to

other channels, or this could damage and defeat the insulation. The

product can only withstand transients up to the transient overvoltage

rating without breakdown or damage to the insulation. An analysis of

the working voltages, loop impedances, temporary overvoltages, and

transient overvoltages in the system must be conducted prior to making

measurements.

Mise en garde

 Ne pas connecter le produit à des signaux dans les

catégories de mesure II, III ou IV et ne pas l'utiliser pour des mesures dans

ces catégories, ou des mesures sur secteur ou sur des circuits dérivés de

surtensions de catégorie II, III ou IV pouvant présenter des surtensions

transitoires supérieures à ce que le produit peut supporter. Le produit

ne doit pas être raccordé à des circuits ayant une tension maximale

supérieure à la tension de fonctionnement continu, par rapport à la

terre ou à d'autres voies, sous peine d'endommager et de compromettre

l'isolation. Le produit peut tomber en panne et son isolation risque

d'être endommagée si les tensions transitoires dépassent la surtension

transitoire nominale. Une analyse des tensions de fonctionnement, des

ni.com

4

NI-9426 Getting Started

Summary of Contents for NI 9426

Page 1: ...NI 9426 Getting Started 2022 07 06...

Page 2: ...ous Voltages 5 Safety Guidelines for Hazardous Locations 5 Electromagnetic Compatibility Guidelines 7 Special Conditions for Marine Applications 7 Preparing the Environment 8 NI 9426 Pinout 8 Connecti...

Page 3: ...on Attention Suivez toutes les instructions et respectez toutes les mises en garde de la documentation d utilisation L utilisation du produit de toute autre fa on que celle sp cifi e risque de l endom...

Page 4: ...the transient overvoltage rating without breakdown or damage to the insulation An analysis of the working voltages loop impedances temporary overvoltages and transient overvoltages in the system must...

Page 5: ...e Measurement Categories CAT I and CAT O are equivalent These test and measurement circuits are for other circuits not intended for direct connection to the MAINS building installations of Measurement...

Page 6: ...aution Substitution of components may impair suitability for Class I Division 2 or Zone 2 Caution The system must be installed in an enclosure certified for the intended hazardous classified location...

Page 7: ...ated in the product specifications These requirements and limits provide reasonable protection against harmful interference when the product is operated in the intended operational electromagnetic env...

Page 8: ...output ports In addition take precautions when designing selecting and installing measurement probes and cables to ensure that the desired EMC performance is attained Preparing the Environment Ensure...

Page 9: ...t signal connection NC No connection Vsup Voltage supply connection Table 1 Signal Descriptions Connecting a Sinking Output Device You can connect 2 and 3 wire sinking output devices to the NI 9426 NI...

Page 10: ...earn about NI service offerings such as calibration options repair and replacement Visit ni com register to register your NI product Product registration facilitates technical support and ensures that...

Reviews: