Channel-to-channel

None

Channel-to-earth ground

Continuous

60 V DC, Measurement Category I

Withstand

Up to 3,000 m altitude

1,000 V RMS, verified by a 5 s dielectric withstand test

Up to 5,000 m altitude

860 V RMS, verified by a 5 s dielectric withstand test

Safety Guidelines for Hazardous Locations

The NI-9403 is suitable for use in Class I, Division 2, Groups A, B, C, D, T4 hazardous

locations; Class I, Zone 2, AEx nA IIC T4 Gc and Ex nA IIC T4 Gc hazardous locations;

and nonhazardous locations only. Follow these guidelines if you are installing the

NI-9403 in a potentially explosive environment. Not following these guidelines may

result in serious injury or death.

Caution

 Do not disconnect I/O-side wires or connectors unless power has

been switched off or the area is known to be nonhazardous.

Caution

 Do not remove modules unless power has been switched off or

the area is known to be nonhazardous.

Caution

 Substitution of components may impair suitability for Class I,

Division 2, or Zone 2.

Caution

 The system must be installed in an enclosure certified for the

intended hazardous (classified) location, having a tool secured cover/door,

where a minimum protection of at least IP54 is provided.

Caution

 For Division 2 and Zone 2 applications, connected signals must

be within the following limits.

ni.com

4

NI-9403 Getting Started

Summary of Contents for NI 9403

Page 1: ...NI 9403 Getting Started 2022 07 06...

Page 2: ...ons 4 Electromagnetic Compatibility Guidelines 5 Special Conditions for Marine Applications 6 Preparing the Environment 6 Connecting the NI 9403 7 Connecting Digital Devices to the NI 9403 7 Overcurre...

Page 3: ...atings for the entire system Safety Guidelines Caution Observe all instructions and cautions in the user documentation Using the product in a manner not specified can damage the product and compromise...

Page 4: ...tentially explosive environment Not following these guidelines may result in serious injury or death Caution Do not disconnect I O side wires or connectors unless power has been switched off or the ar...

Page 5: ...ated voltage value of 85 V at the supply terminals to the equipment Caution The system shall only be used in an area of not more than Pollution Degree 2 as defined in IEC EN 60664 1 Caution The system...

Page 6: ...s Some products are approved for marine shipboard applications To verify marine approval certification for a product visit ni com product certifications search by model number and click the appropriat...

Page 7: ...DIO15 RSVD 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 Signal Name Description DIO Each channel includes a DIO pin to which you can connect a...

Page 8: ...dule sets all the DIO channels to high impedance for approximately 280 ms When the channels are in an overcurrent state the NI 9403 can accept new line direction configuration and output state data bu...

Page 9: ...ion downloads and troubleshooting and application development self help such as tutorials and examples Visit ni com services to learn about NI service offerings such as calibration options repair and...

Reviews: