background image

2. Install a clamp-on ferrite bead on the shield ground wire between the cable

and the ground lug. You can use one ferrite bead per device for all cables.

Where to Go Next

CompactRIO

NI CompactDAQ

Located at

 

ni.com/manuals

RELATED INFORMATION

C Series Documentation
& Resources
ni.com/info    cseriesdoc   

Services
ni.com/services

Installs with the software

NI 9212 Datasheet 

NI-RIO Help

LabVIEW FPGA Help

NI 9212 Datasheet 

NI-DAQmx Help

LabVIEW Help

Worldwide Support and Services

The NI website is your complete resource for technical support. At 

ni.com/support

,

you have access to everything from troubleshooting and application development

self-help resources to email and phone assistance from NI Application Engineers.
Visit 

ni.com/services

 for NI Factory Installation Services, repairs, extended warranty,

and other services.
Visit 

ni.com/register

 to register your NI product. Product registration facilitates

technical support and ensures that you receive important information updates from

NI.
A Declaration of Conformity (DoC) is our claim of compliance with the Council of the

European Communities using the manufacturer’s declaration of conformity. This

system affords the user protection for electromagnetic compatibility (EMC) and

product safety. You can obtain the DoC for your product by visiting 

ni.com/

certification

. If your product supports calibration, you can obtain the calibration

certificate for your product at 

ni.com/calibration

.

© National Instruments

15

NI-9212

Summary of Contents for NI 9212

Page 1: ...NI 9212 2023 06 07...

Page 2: ...arine Applications 8 Preparing the Environment 9 TB 9212 Pinout 9 NI 9212 Connection Guidelines 10 Minimizing Thermal Gradients 10 NI 9212 and TB 9212 with Screw Terminal Thermocouple Connection 11 NI...

Page 3: ...nt in the system to determine the safety and EMC ratings for the entire system 2015 2016 National Instruments Corporation All rights reserved Refer to the National Instruments _Legal Information direc...

Page 4: ...ts on the same module Caution Ensure that devices and circuits connected to the module are properly insulated from human contact Caution When module terminals are hazardous voltage LIVE 42 4 Vpk 60 VD...

Page 5: ...ion system referred to as MAINS voltage MAINS is a hazardous live electrical supply system that powers equipment This category is for measurements of voltages from specially protected secondary circui...

Page 6: ...tinuous 60 VDC Measurement Category I Withstand 1 000 Vrms Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as...

Page 7: ...azardous Caution Do not remove modules unless power has been switched off or the area is known to be nonhazardous Caution Substitution of components may impair suitability for Class I Division 2 Cauti...

Page 8: ...ith the regulatory requirements and limits for electromagnetic compatibility EMC stated in the product specifications These requirements and limits provide reasonable protection against harmful interf...

Page 9: ...r filtered power and input output ports In addition take precautions when designing selecting and installing measurement probes and cables to ensure that the desired EMC performance is attained Prepar...

Page 10: ...conducting heat directly to terminal junctions can cause thermal gradients Observe the following guidelines to minimize thermal gradients and improve the system accuracy Use small gauge thermocouple...

Page 11: ...ermocouple Connection Thermocouple TC TC Shield TB 9212 NI 9212 Ground Lug NI 9212 and TB 9212 with Mini TC Thermocouple Connection Caution Electrostatic Discharge ESD can damage the TB 9212 with mini...

Page 12: ...ximum torque of 0 4 N m 3 6 lb in Do not overtighten the jackscrews Wiring the TB 9212 with screw terminal What to Use TB 9212 with screw terminal 0 05 mm to 0 5 mm 30 AWG to 20 AWG wire with 5 1 mm 0...

Page 13: ...no exposed wire extends past the screw terminal 3 Route the wire through the TB 9212 with screw terminal opening remove slack from the wiring and secure the wires using a zip tie 4 Replace the foam pa...

Page 14: ...orque of 0 4 N m 3 6 lb in Do not overtighten the jackscrews Connecting the TB 9212 with mini TC What to Use TB 9212 with mini TC Shielded thermocouple Clamp on ferrite bead part number 781233 01 What...

Page 15: ...t self help resources to email and phone assistance from NI Application Engineers Visit ni com services for NI Factory Installation Services repairs extended warranty and other services Visit ni com r...