 Open the terminal by pressing the push button when using stranded wire

without a ferrule.

High-Vibration Application Connections

If your application is subject to high vibration, NI recommends that you use the

NI-9940 backshell kit to protect connections to the NI-9207 with spring terminal.

Overvoltage Protection

The NI-9207 provides overvoltage protection for each channel.

Note

 Refer to the NI-9207 Specifications on 

ni.com/manuals

 for more

information about overvoltage protection.

Where to Go Next

CompactRIO

NI CompactDAQ

RELATED INFORMATION

C Series Documentation
& Resources
ni.com/info cseriesdoc

Services
ni.com/services

NI 9207 Datasheet

NI-RIO Help

LabVIEW FPGA Help

NI 9207 Datasheet

NI-DAQmx Help

LabVIEW Help

Installs with the software

Located at

 

ni.com/manuals

NI Services

Visit 

ni.com/support

 to find support resources including documentation,

downloads, and troubleshooting and application development self-help such as

tutorials and examples.

ni.com

10

NI-9207 Getting Started

Summary of Contents for NI-9207

Page 1: ...NI 9207 Getting Started 2022 07 01...

Page 2: ...e Applications 6 Preparing the Environment 6 NI 9207 7 Floating Differential Connections 7 Grounded Connections 8 Single Ended Connections 8 Connecting an External Power Supply 8 Connecting a Loop Pow...

Page 3: ...o the documentation for each component in the system to determine the safety and EMC ratings for the entire system Safety Guidelines Caution Observe all instructions and cautions in the user documenta...

Page 4: ...up to 5 000 m 500 V RMS verified by a 5 s dielectric withstand test Safety Guidelines for Hazardous Locations The NI 9207 is suitable for use in hazardous locations and hazardous locations and nonhaz...

Page 5: ...rdous locations in ambient temperatures of 40 C Ta 70 C If you are using the NI 9207 in Gas Group IIC hazardous locations you must use the device in an NI chassis that has been evaluated as Ex nC IIC...

Page 6: ...in the product documentation Furthermore any changes or modifications to the product not expressly approved by National Instruments could void your authority to operate it under your local regulatory...

Page 7: ...AI3 AI1 Vsup Vsup Vsup Vsup Vsup AI6 AI4 AI2 AI0 Vsup Vsup Vsup Vsup Vsup AI7 AI5 AI3 AI1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 Table 1 Si...

Page 8: ...ing an External Power Supply You must connect an external power supply with a 0 to 30 V voltage range to the NI 9207 This power supply provides the current for the devices you connect to the module Yo...

Page 9: ...ire Current Transducer OUT NI 9207 COM AI8 External Power Supply Vsup COM Vsup 2 A Max NI 9207 Connection Guidelines Make sure that devices you connect to the NI 9207 are compatible with the module sp...

Page 10: ...9207 Specifications on ni com manuals for more information about overvoltage protection Where to Go Next CompactRIO NI CompactDAQ RELATED INFORMATION C Series Documentation Resources ni com info cser...

Page 11: ...gister to register your NI product Product registration facilitates technical support and ensures that you receive important information updates from NI NI corporate headquarters is located at 11500 N...

Reviews: