background image

 0.08 mm to 1.0 mm (28 AWG to 18 AWG) copper conductor wire with 7 mm

(0.28 in.) of insulation stripped from the end

Flathead screwdriver with a 2.3 mm x 1.0 mm (0.09 in. x 0.04 in.) blade,

included with the NI-9206

What to Do

Complete the following steps to connect wires to the spring-terminal connector.

1

2

3

1. Insert the screwdriver into a spring clamp activation slot to open the

corresponding connector terminal.

2. Press a wire into the open connector terminal.
3. Remove the screwdriver from the activation slot to clamp the wire into place.

High-Vibration Application Connections

If your application is subject to high vibration, NI recommends that you use the

cRIO-9941 backshell kit to protect connections to the NI-9206.

ni.com

8

NI-9206 Getting Started

© 2023 National Instruments Corporation.