NI 9157/9159 Operating Instructions and Specifications
18
ni.com
Physical Characteristics
If you need to clean the chassis, wipe it with a dry towel.
Screw-terminal wiring ............................12–18 AWG copper conductor
wire with 10 mm (0.39 in.) of
insulation stripped from the end
Torque for screw terminals.....................0.5 to 0.6 N · m
(4.4 to 5.3 lb · in.)
Chassis weight ........................................2,231 g (78.7 oz)
Environmental
The NI 9157/9159 is intended for indoor use only.
Operating temperature
(IEC-60068-2-1 and IEC-60068-2-2) .....0 °C to 55 °C
Note
Refer to the mounting instructions in the
section of
this document. Failure to follow the mounting instructions in that section can cause
temperature derating. For more information about mounting configurations and
temperature derating, go to
ni.com/info
and enter the Info Code
criomounting
.
Storage temperature
(IEC-60068-2-1 and IEC-60068-2-2) .....–40 °C to 85 °C
Ingress protection ...................................IP 40
Operating humidity
(IEC-60068-2-56) ...................................10 to 90% RH, noncondensing
Storage humidity
(IEC-60068-2-56) ...................................5 to 95% RH, noncondensing
Maximum altitude...................................2,000 m
Pollution Degree (IEC 60664) ................2