USER GUIDE

NI 653

x

 Cable Adapter

The NI 653

x

 cable adapter interfaces with National Instruments high-speed 

digital I/O (DIO) devices. The cable adapter provides an easy way to 
connect the Very High Density Connector Interface (VHDCI) connectors, 
labeled as 

Digital Data & Control,

 on the newer NI 6535/6536/6537 

devices

 

to the 68-pin DAQ connectors found on older NI 6533/6534 

accessories and fixturing. The 653

x

 cable adapter is also compatible with 

the NI 654

x

 and NI 655

x

 digital pattern generator/analyzer devices.

For best signal integrity, NI recommends using the NI 6535/6536/6537 
devices with newer accessories such as the NI CB-2162 and NI SMB-2163.

This guide explains how to set up and use the NI 653

x

 cable adapter.

Contents

What You Need to Get Started ............................................................... 2
Related Documentation........................................................................... 2
Parts Locator Diagram ............................................................................ 3
Installing Cables...................................................................................... 4
Removing the NI 653

x

 Cable Adapter from its Enclosure ..................... 5

Connecting Signals ................................................................................. 6

Custom Wiring Example ................................................................. 11

Specifications .......................................................................................... 13

Digital I/O ........................................................................................ 13
Traces............................................................................................... 13
Power ............................................................................................... 13
Physical ............................................................................................ 13

Where to Go for Support......................................................................... 14

Summary of Contents for NI 6535

Page 1: ...e adapter is also compatible with the NI 654x and NI 655x digital pattern generator analyzer devices For best signal integrity NI recommends using the NI 6535 6536 6537 devices with newer accessories...

Page 2: ...ferent aspects of the device The titles and location of the documents vary based on the driver that supports the NI device but you should have the following types of documentation Getting Started Guid...

Page 3: ...gure 1 NI 653x Cable Adapter Parts Locator Diagram 1 Enclosure Base 2 Jacksockets M2 5 Screw 2 56 Socket 3 68 Pin DAQ Connector 4 Enclosure Top Cover 5 M2 5 x 6 mm Philips Flathead Countersunk Screws...

Page 4: ...ot liable for damage resulting from improper connections Refer to Figure 2 as you complete the following steps to install the cable adapter 1 Insert the cable into the cable adapter 2 Tighten the cabl...

Page 5: ...its enclosure complete the following steps 1 Remove the screws from the cable adapter enclosure top cover as shown in Figure 3 Figure 3 Remove Screws from the Enclosure 2 Remove the enclosure top cov...

Page 6: ...0 7 from the NI 6533 6534 68 pin DAQ connector are connected to an 8 position screw terminal PFI channels must be manually connected through screw terminals for flexibility and to ensure correct sign...

Page 7: ...e 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 DIO...

Page 8: ...41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 5 V PFI 2 PFI 6 PFI 0 PFI 4 PFI 5 PFI 1 PFI 7 PFI 3 P0 0 GND P0 3 P0 4 GND P0 7 P1 0 P1 1 GND R GND GND P1 6 P1 7 P2...

Page 9: ...0 7 or P3 0 7 on a 68 pin DAQ connector PFI 0 5 Programmable functional interface PFI channels 0 through 5 6 position screw terminal J4 GND Ground reference for signals RESERVED These channels are res...

Page 10: ...hipped with the NI high speed DIO device NI is not liable for any damage resulting from such signal connections Table 3 shows the relationship between PFI channels and the termination sockets Note Ref...

Page 11: ...NI 6533 6534 Without changing the fixture setup the adapter and software can be changed to maintain functionality The NI 653x cable adapter can be configured using 22 to 26 gauge wire as shown in Fig...

Page 12: ...34 Burst Handshaking Application Figure 9 shows the changes made to this LabVIEW VI to accommodate the NI 653x cable adapter connections and provide compatibility with the previous application using a...

Page 13: ...Physical Dimensions 62 7 69 3 16 7 mm 2 47 2 73 0 66 in I O connectors 68 pin VHDCI connector 6 position screw terminal 8 position screw terminal 68 pin DAQ connector Recommended wire gage 22 26 AWG R...

Page 14: ...support outside the United States contact your local branch office Australia 1800 300 800 Austria 43 0 662 45 79 90 0 Belgium 32 0 2 757 00 20 Brazil 55 11 3262 3599 Canada 800 433 3488 China 86 21 6...

Page 15: ...nal Instruments trademarks Other product and company names mentioned herein are trademarks or trade names of their respective companies For patents covering National Instruments products refer to the...

Reviews: