background image

Figure 2. NI 5751 Digital Connector Pinout

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

DO 1

GND

GND

GND

GND

GND

GND

DO 3

DO 5

DO 7

DI 1

DI 3

DI 5

DI 7

DO 0

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

GND

DO 2

DO 4

DO 6

DI 0

DI 2

DI 4

DI 6

GND

GND

GND

GND

GND

GND

35

36

37

38

39

40

41

42

43

44

45

46

47

48

49

50

51

52

53

54

55

56

57

58

59

60

61

62

63

64

65

66

67

68

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

The following figure shows the pinout for the analog connector on the front panel of

the NI 5751/5751B.

© National Instruments

11

NI-5751/5751B

Summary of Contents for NI 5751

Page 1: ...NI 5751 5751B 2022 07 11...

Page 2: ...6 Accessories 6 Unpacking 7 Preparing the Environment 8 Confirming that Measurement Automation Explorer MAX Recognizes the Device 8 Installing the NI 5751 5751B 9 Cables 9 Front Panel and Connector P...

Page 3: ...or FlexRIO The NI 5751 variant is compatible with the NI PXI 795xR and NI PXIe 796xR FPGA modules only Note NI 5751R refers to the combination of your NI 5751 5751B adapter module and either a FlexRIO...

Page 4: ...ots You can order a kit of six single slot EMC Filler Panels directly from NI by visiting ni com Caution To ensure the specified EMC performance the length of all I O cables must be no longer than 30...

Page 5: ...the FPGA module front panel connectors and I O controller for FlexRIO front panel connectors and I O programming instructions and adapter module component level IP CLIP FlexRIO Adapter Module Develop...

Page 6: ...The following table lists each adapter module s compatibility with FlexRIO FPGA modules and controllers for FlexRIO NI PXI 795xR NI PXIe 796xR NI PXIe 797xR NI 793xR NI 5751 Yes Yes No No NI 5751B Ye...

Page 7: ...NI SMB 2148 4 SHC68 C68 D4 Cable Assemblies Unpacking Caution To prevent ESD from damaging the devices ground yourself using a grounding strap or by holding a grounded object such as your computer cha...

Page 8: ...noncondensing Pollution Degree 2 Maximum altitude 2 000 m at 25 C ambient temperature Indoor use only Note Refer to the NI 5751 5751B Specifications at ni com manuals for complete specifications Cauti...

Page 9: ...the device is correctly installed and restart 4 Controllers for FlexRIO only Your device appears under the Remote Devices section Installing the NI 5751 5751B Refer to the getting started guide for y...

Page 10: ...powering down the module and connect signals only after the adapter module has been powered on by the FlexRIO FPGA module or controller for FlexRIO Caution Connections that exceed any of the maximum r...

Page 11: ...D GND GND GND GND GND GND GND GND GND DO 2 DO 4 DO 6 DI 0 DI 2 DI 4 DI 6 GND GND GND GND GND GND 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 1...

Page 12: ...GND AI 4 GND AI 6 GND AI 8 AI 10 GND AI 12 AI 14 GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND GND AI 1 AI 3 AI 5 AI 7 AI 9 AI 11 AI 13 AI 15 GND GND GND GND GND GND...

Page 13: ...XIe backplane If you change the frequency of Sync Clock DStarA or CLK IN when used as the Sample Clock you must assert Force Initialization CLK IN front panel SMB If you change the frequency of Sync C...

Page 14: ...ress SPI Write Data Force Initialization Initialization Done PLL Unlocked ADC Error A ADC Error B SPI Engine NI 5751 Adapter Module LabVIEW FPGA CLIP Data Clock ADC Control Component Level Intellectua...

Page 15: ...clock through the front panel SMB connector This CLIP only supports external Sample Clock rates from 30 MHz to 50 MHz Each 14 bit sample is output to LabVIEW as an I16 data type The 14 bit data is lef...

Page 16: ...ngstarted Available from the Start menu FlexRIO Help Getting Started with LabVIEW LabVIEW FPGA Module Help NI 5751 5751B Specifications FlexRIO Module Development Kit User Manual DISCOVER CREATE LEARN...

Page 17: ...our product at ni com calibration NI corporate headquarters is located at 11500 North Mopac Expressway Austin Texas 78759 3504 NI also has offices located around the world For telephone support in the...