© National Instruments
|
6-5
NI 17xx Smart Camera User Manual
IP RESET Switch
To clear the NI Smart Camera IP settings, move the IP RESET switch to the ON position and
reapply power or restart the smart camera. Use the IP RESET switch to reset the TCP/IP settings
when moving the camera from one subnet to another or when the current TCP/IP settings are
otherwise invalid.
Starting the smart camera with the IP RESET switch in the ON position resets the IP address to
0.0.0.0
. Once you have reset the IP address, you can set up a new network configuration for
the smart camera from a development machine on the same subnet, or you can use an Ethernet
cable to connect the smart camera directly to the development computer. Refer to
Getting Started
with the NI 17xx Smart Camera
for information about assigning an IP address to the smart
camera.
To resume normal operations, move the IP RESET switch to the OFF position and reapply power
or restart the smart camera. Keep the IP RESET switch in the OFF position during normal
operation.
NO APP Switch
Move the NO APP switch to the ON position to prevent a startup application from running when
the NI Smart Camera powers on. If you want to permanently disable the application from
running when the smart camera powers on, you can disable the startup application in software.
To automatically run an application when the smart camera powers on, keep the NO APP switch
in the OFF position. You must configure the application in software to automatically run when
the smart camera powers on. Refer to the
LabVIEW Real-Time Module Help
for more
information about automatically launching VIs when the smart camera powers on. Refer to the
NI Vision Builder for Automated Inspection: Configuration Help
for more information about
configuring remote target options.
Keep the NO APP switch in the OFF position during normal operation.