Section Six
IBIC
©National Instruments Corp.
6-5
GPIB-PC User Manual
Applications Monitor Options
When displayed, the applications monitor allows you to view the
parameters of the current GPIB call, change the display and trap modes,
and scan the GPIB session summary. The monitor displays the
following information pertinent to the current GPIB call:
Device
symbolic device name.
Function
GPIB-PC function mnemonic and description.
Value
for functions that have a number as their second
parameter, this contains its value, otherwise it is
undefined.
Count
for functions that have a count as their third
parameter this contains its value, otherwise it is
undefined.
IBSTA
contains the GPIB status information.
IBERR
contains the GPIB error information, or the
previous value of the value parameter if no error
occurred.
IBCNT
contains the number of bytes transferred.
Buffer
for functions that have a buffer as a parameter, this
Value
displays its contents. Each byte of the buffer is
shown with its index, character image, and ASCII
value.
Status
shows the state of the individual bits of
IBSTA
. A
"*" indicated the bit is active. The active bits of
the trap mask are highlighted for easy
identification.
Error
shows the state of the individual bits of
IBERR
. A
"*" indicates the bit is active.
Information
contains any message concerning the current GPIB
call.