BASICA/QuickBASIC GPIB-PC Function Calls
Section Four A
GPIB-PC User Manual
4A-86
©National Instruments Corp.
Device Example:
1.
Wait indefinitely for the device
LOGGER%
to request service.
100 MASK% = &H800
' RQS
110 CALL IBWAIT (LOGGER%,MASK%)
Board Examples:
1.
Wait for a service request or a timeout.
100 MASK% = &H5000
' TIMO SRQI
110 CALL IBWAIT (BD%,MASK%)
120 REM Check IBSTA% here to see which
130 REM occurred.
2.
Update the current status for
IBSTA%
.
100 MASK% = 0
110 CALL IBWAIT (BD%,MASK%)
3.
Wait indefinitely until control is passed from another CIC.
100 MASK% = &H20
' CIC
110 CALL IBWAIT (BD%,MASK%)
4.
Wait indefinitely until addressed to talk or listen by another
CIC.
100 MASK% = &H0C
' TACS LACS
110 CALL IBWAIT (BD%,MASK%)