Specifications
This appendix lists the electrical, environmental, and physical
characteristics of the GPIB-1284CT, along with recommended operating
conditions.
Electrical Characteristics
AC Version
Power supply unit
100–120 VAC ±10% ...................... 50–60 Hz
220–240 VAC ±10% ...................... 50–60 Hz
Current requirement
100–120 VAC ................................. 55 mA
220–240 VAC ................................. 45 mA
Fuse rating and type
100–120 VAC ................................. 300 mA, UL/CSA approved
220–240 VAC ................................. 500 mA, IEC approved
DC Version
DC input ................................................. +5 to +13 VDC, regulated
Minimum current requirement ............... 700 mA
Environmental Characteristics
Operating temperature............................ 0 to 40 °C
Storage temperature ............................... 0 to 70 °C
Relative humidity ................................... 10% to 95%, noncondensing
EMI ........................................................ FCC Class A Verified