3.
Ground yourself with a grounding strap or touch a grounded metal surface.
4.
Unlatch the module by pushing down on the ejector handle.
5.
Hold the module by the ejector handle and remove it from the slot.
Store the module in the original antistatic packaging when not in use to avoid damage.
Environment
............................................................................
Maximum altitude
2,000 m (800 mbar) (at 25 °C ambient
temperature)
............................................................................
Pollution Degree
2
Indoor use only.
Operating Environment
............................................................................
Ambient temperature range
0 °C to 55 °C (Tested in accordance with
IEC-60068-2-1 and IEC-60068-2-2.)
............................................................................
Relative humidity range
10% to 90%, noncondensing (Tested in
accordance with IEC-60068-2-56.)
Storage Environment
............................................................................
Ambient temperature range
-20 °C to 70 °C (Tested in accordance
with IEC-60068-2-1 and IEC-60068-2-2.)
............................................................................
Relative humidity range
5% to 95%, noncondensing (Tested in
accordance with IEC-60068-2-56.)
Shock and Vibration
............................................................................
Operating shock
30 g peak, half-sine, 11 ms pulse (Tested in
accordance with IEC-60068-2-27. Meets
MIL-PRF-28800F Class 2 limits.)
Random vibration
....................................................................
Operating
5 Hz to 500 Hz, 0.3 g
rms
....................................................................
Nonoperating
5 Hz to 500 Hz, 2.4 g
rms
(Tested in accordance
with IEC-60068-2-64. Nonoperating test
profile exceeds the requirements of
MIL-PRF-28800F, Class 3.)
18
|
ni.com
|
NI 6581/6581B Getting Started Guide