4-2
|
ni.com
Chapter 4
Deployment
Use the NI CVS-1459RT serial number to uniquely identify each unit. The serial number is
printed on the top side of each NI CVS-1459RT.
The configuration environment on the host machine displays these values in order to distinguish
one NI CVS-1459RT from another. In addition to distinguishing units based on serial number,
you can also assign each NI CVS-1459RT a descriptive name in the configuration environment.
The default name for each device is
NI-CVS1459RT-XXXXXXXX
, where
XXXXXXXX
is
the eight digit serial number.
When configured to run an inspection, the NI CVS-1459RT can run autonomously without
connection to the host machine. All image acquisition, inspection, decision making, and I/O
occurs on the NI CVS-1459RT device itself. For local monitoring of the inspection, you can
connect a monitor directly to the VGA connector on the NI CVS-1459RT, as shown in
Figure 4-2.
Figure 4-2.
NI CVS-1459RT Connected to a Monitor
At any time, you can reconnect the host machine to the NI CVS-1459RT device and remotely
monitor progress.